User Manual
70
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
Field
Bits
Type
Description
RES
31:27
r
Reserved
Always read as 0
CYC_SENSE_S_DEL
26:24
rw
Sample Delay in Cyclic Sense Mode
Delay time after HS/VDDEXT is turned to beginning of
sensing window for MONx/GPIOx. The sensing window
is fixed to 10 µs.
000
B
is 10 µs
001
B
is 20 µs
010
B
is 30 µs
011
B
is 40 µs
100
B
is 60 µs
101
B
is 80 µs
110
B
is 100 µs
111
B
is 150 µs
RES
23:22
r
Reserved
Always read as 0
CYC_WAKE_E01
21:20
rw
Exponent
00
B
Exponent value is 0
01
B
Exponent value is 1
10
B
Exponent value is 2
11
B
Exponent value is 3
CYC_WAKE_M03
19:16
rw
Mantissa
Mantissa value is calculated as CYC_WA1
0000
B
Mantissa value is 1
1111
B
Mantissa value is 16
RES
15
r
Reserved
Always read as 0
RES
14
r
Reserved
Always read as 0
CYC_SENSE_E01
13:12
rw
Exponent
00
B
Exponent value is 0
01
B
Exponent value is 1
10
B
Exponent value is 2
11
B
Exponent value is 3
31
27
r
RES
26
24
rw
CYC_SENSE_
S_DEL
23
22
r
RES
21
20
rw
CYC_WAK
E_E01
19
16
rw
CYC_WAKE_M03
15
15
r
RES
14
14
r
RES
13
12
rw
CYC_SEN
SE_E01
11
8
rw
CYC_SENSE_M03
77
r
RES
6
5
r
RES
44
rw
RFU
33
rw
CYC_
SEN*
22
rw
CYC_
WAK*
11
rw
EN_0
V9_N
00
rw
WAKE
_W_*