User Manual
700
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Measurement Core Module (incl. ADC2)
Measurement Unit Control Register 2
This register is used for controlling the calibration unit of channels 0-7 of the measurement core module. This
registers are protected for the purpose mentioned at the beginning of this chapter. Furthermore this register
contains the sample time adjustment for ADC2. The default value is 14 clock cycles. Values above 14 clock
cycles are not recommended, because they increase the overall response time of the measurement system.
Field
Bits
Type
Description
RES
31:7
r
Reserved
Always read as 0
CALIB_EN_6_0
6:0
rwpt
Calibration Enable for Channels 6 to 0
The following values can be ored:
000 0001
B
CH0_EN
, Channel 0 calibration enable
000 0010
B
CH1_EN
, Channel 1 calibration enable
000 0100
B
CH2_EN
, Channel 2 calibration enable
000 1000
B
CH3_EN
, Channel 3 calibration enable
001 0000
B
CH4_EN
, Channel 4 calibration enable
010 0000
B
CH5_EN
, Channel 5 calibration enable
100 0000
B
CH6_EN
, Channel 6 calibration enable
Table 372 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
00000000
H
RESET_TYPE_4
ADC2_CTRL2
Offset
Reset Value
Measurement Unit Control Register 2
18
H
see
Field
Bits
Type
Description
RES
31:16
r
Reserved
Always read as 0
RES
15:12
r
Reserved
Always read as 0
31
16
r
RES
15
12
r
RES
11
8
rw
SAMPLE_TIME_i
nt
77
r
MCM_
RDY
6
5
r
RES
4
1
r
RES
00
rwpt
MCM_
PD_N