User Manual
739
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Measurement Core Module (incl. ADC2)
Upper Counter Trigger Level Channel 0 - 3
ADC2_CNT0_3_UPPER
Offset
Reset Value
Upper Counter Trigger Level Channel 0 - 3
A4
H
see
Field
Bits
Type
Description
RES
31:29
r
Reserved
Always read as 0
HYST_UP_CH3
28:27
rw
Channel 3 upper hysteresis
0
H
HYSTOFF
, hysteresis switched off
1
H
HYST4
, hysteresis = 4
2
H
HYST8
, hysteresis = 8
3
H
HYST16
, hysteresis = 16
CNT_UP_CH3
26:24
rw
Upper timer trigger threshold channel 3
0
H
1 measurement
1
H
2 measurements
2
H
4 measurements
3
H
8 measurements
4
H
16 measurements
5
H
32 measurements
6
H
63 measurements
7
H
63 measurements
RES
23:21
r
Reserved
Always read as 0
HYST_UP_CH2
20:19
rw
Channel 2 upper hysteresis
0
H
HYSTOFF
, hysteresis switched off
1
H
HYST4
, hysteresis = 4
2
H
HYST8
, hysteresis = 8
3
H
HYST16
, hysteresis = 16
31
29
r
RES
28
27
rw
HYST_UP
_CH3
26
24
rw
CNT_UP_CH3
23
21
r
RES
20
19
rw
HYST_UP
_CH2
18
16
rw
CNT_UP_CH2
15
13
r
RES
12
11
rw
HYST_UP
_CH1
10
8
rw
CNT_UP_CH1
7
5
r
RES
4
3
rw
HYST_UP
_CH0
2
0
rw
CNT_UP_CH0