User Manual
938
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Side Switch
HS2_OL_STS
30
rwhxr
High Side 2 Open Load Interrupt Status
0
B
no Open Load
, no open load Condition occurred.
1
B
Open Load
, open load occurred; switch is not
automatically shutdown. Write sets status.
HS2_OT_STS
29
rwhxr
High Side 2 Overtemperature Status
0
B
no Overtemperature
, no overtemperature
occurred.
1
B
Overtemperature
, overtemperature occurred;
switch is automatically shutdown. Write sets status.
RES
28:24
r
Reserved
Always read as 0
HS2_OC_IS
23
rwhxr
High Side 2 Overcurrent Interrupt Status
0
B
no Overcurrent
, no overcurrent Condition
occurred.
1
B
Overcurrent
, overcurrent occurred; switch is
automatically shutdown. Write sets status.
HS2_OL_IS
22
rwhxre
High Side 2 Open Load Interrupt Status
0
B
NORMAL
, normal load
1
B
OPEN LOAD
, open load detected, write sets status
HS2_OT_IS
21
rwhxre
High Side 2 Overtemperature Interrupt Status
0
B
no Overtemperature
, no overtemperature
occurred.
1
B
Overtemperature
, overtemperature occurred;
switch is automatically shutdown. Write sets status
RES
20:15
r
Reserved
Always read as 0
HS1_OL_STS
14
rwhxr
High Side 1 Open Load Interrupt Status
0
B
no Open Load
, no open load Condition occurred.
1
B
Open Load
, open load occurred; switch is not
automatically shutdown. Write sets status.
HS1_OT_STS
13
rwhxr
High Side 1 Overtemperature Status
0
B
no Overtemperature
, no overtemperature
occurred.
1
B
Overtemperature
, overtemperature occurred;
switch is automatically shutdown. Write sets status.
RES
12:8
r
Reserved
Always read as 0
HS1_OC_IS
7
rwhxr
High Side 1 Overcurrent Interrupt Status
0
B
no Overcurrent
, no overcurrent Condition
occurred.
1
B
Overcurrent
, overcurrent occurred; switch is
automatically shutdown. Write sets status.
HS1_OL_IS
6
rwhxre
High Side 1 Open Load Interrupt Status
0
B
NORMAL
, normal load
1
B
OPEN LOAD
, open load detected, write sets status
Field
Bits
Type
Description