Microcontroller with LIN and Power Switches for Automotive Applications
Capture/Compare Unit 6 (CCU6)
18.3.6
T12 Shadow Register Transfer
A special shadow transfer signal (T12_ST) can be generated to facilitate updating the period and compare
values of the compare channels CC60, CC61, and CC62 synchronously to the operation of T12. Providing a
shadow register for values defining one PWM period facilitates a concurrent update by software for all relevant
parameters. The next PWM period can run with a new set of parameters. The generation of this signal is
requested by software via bit TCTR0.STE12 (set by writing 1 to the write-only bit TCTR4.T12STR, cleared by
writing 1 to the write-only bit TCTR4.T12STD).
shows the shadow register structure and the shadow transfer signals, as well as on the read/write
accessibility of the various registers.
Figure 140 T12 Shadow Register Overview
CCU6_MCA05546
Compare Register
CC6xR
Compare Shadow
Register CC6xSR
>1
_
Other Modes
(Hall, Capture, etc.)
Period Register
T12PR
Period Shadow
Register T12PR
COUT6xPS
COUT6xPS
Shadow
(T12)
PSLy
(T12) PSLy
Shadow
CC6xPS
CC6xPS
Shadow
T12_ST
Write
Read
Read
Read
Read
Write
Write
Write
Read
Write
Read