manualshive.com logo in svg
background image

 

Release 2.0.x version 1.3 

Smart Home Controller 2.0 

 
 
 
 
 

 

 
 
 

Quick Installation Manual with MRF 

 

 

 

Содержание Smart Home Controller 2.0

Страница 1: ...Release 2 0 x version 1 3 Smart Home Controller 2 0 Quick Installation Manual with MRF...

Страница 2: ...ve SHC Configuration in original MRF Project 16 4 Troubleshooting 17 4 1 First check Most important 17 4 2 Basic Health check 17 4 3 LED Indicators on the Smart Home Controller Box 18 4 4 How to resto...

Страница 3: ...Quick Installation Manual with MRF Page 3 of 24 Appendix B Feedback form 24...

Страница 4: ...t this document This manual is intended for trained Installers only and describes the quick installation and configuration of new Smart Home Controller 2 x projects with MRF Following this manual will...

Страница 5: ...Avoid disturbance from other equipment like WiFi routers Minimum distance 0 5m Installation steps 1 Use the mounting holes in the SHC to screw the SHC to the wall 2 Connect the SHC to your home netwo...

Страница 6: ...ic Use the new generation Actuators with Extended Status Messaging support to increase the status reliability at hot spots MRF Project installation steps 1 Create the Project topology Insert a backgro...

Страница 7: ...to 55 minutes G Room Controller Send Temperature value Send Humidity value Cyclic sending Note Per default the SHC Climate Function expects within every hour a temperature value Set the protection tim...

Страница 8: ...nnected to the SHC are indicated by a light blue dashed line 7 SHC settings A Right click on the SHC Icon and select Settings B Select Tab Devices Zones C Import the Project Topology as SHC Zones and...

Страница 9: ...in MRF 2 Function Light Heating Window Door Consumption 3 Extra 1 Contact type Unit 4 Extra 2 Custom ON System default if not set ON CLOSED MOTION 5 Extra 3 Custom OFF System default if not set OFF O...

Страница 10: ...nd checked for updates If not follow Appendix A Activate and check for updates Find also detailed information in the SHC Help file SHC Setup steps 1 Login into the Web Admin Console See section 4 7 Wa...

Страница 11: ...check option Advanced F To enable remote access check option Remote Remote access is only possible when Global Remote Access is enabled See Appendix A section A 1 step 5 Enable Global Remote Access 4...

Страница 12: ...or the Night Orientation See help file 5 3 2 Macros C Create some planner events to switch the lights automatically See help file 5 1 Tab Planner D Enable and configure the Alarm Function if needed Se...

Страница 13: ...nload and connect the App This example is based on the iPhone Figure 1 Download App Open the App Store Search for Eaton Install and open the App Figure 2 Connect to Smart Home Controller when in the s...

Страница 14: ...ontrol Select the Climate Function Figure 3 Start the Temperature Control Click Edit Select Heating And Close Select a predefined mode The question mark indicates that no temperature value has been re...

Страница 15: ...t the Status Control Function to set the preferred light settings Figure 4 Create a Light Scene 1 Select Status Control Set preferred Lights Select Scene Function And click Edit Click Figure 5 Create...

Страница 16: ...le to restore the SHC configuration 2 Open the original used MRF Project for your SHC in the new MRF V2 42 or higher 3 Right click on the Smart Home Controller and select Scan Device new Only necessar...

Страница 17: ...on local network have no internet access 3 Is the Global Remote Access enabled Enable Global Remote Access Menu Diagnostics System Status Enable the Remote for User admin Menu System Users 3a Initial...

Страница 18: ...net connection via a PC or laptop RF Traffic LED o Blinking Green RF traffic System Message LED o Green There are no new messages in the Mailbox o Yellow New Warning Message in the Mailbox o Red New E...

Страница 19: ...the System by removing the power plug for 1 minute and reconnect Reboot the Smart Home Controller via the Web Admin Console Set the Smart Home Controller back to factory settings Reconfigure everythi...

Страница 20: ...th the login page 4 8 Default admin password The default password for admin is admin Please change this password directly after the setup 4 9 Diagnostics Status bar Indicators and colors In the top ba...

Страница 21: ...ew Messages available in the System Log o Green No new messages after the last check o Yellow New Warning messages o Red New Error messages Battery status battery powered Devices o Green All batteries...

Страница 22: ...nd Accept the Terms And Conditions Accept 4 Please wait until the popup disappears 5 Enable Global Remote Access 6 Refresh the page to check the connection status 7 Please make a note of the received...

Страница 23: ...SW update a new version of the RF module firmware should become available Always install the new firmware in this case the Update button is available a Open Tab 1 Diagnostics System Status SHC 2 0 me...

Страница 24: ...Email Address Used Smartphone Tablet and browsers iPhone App iOS Version iPad App iOS Version Andoid Phone App Android Version Andoid Pad App Android Version Safari Browser Version Google Chrome Brows...

Отзывы: