FX3DH - 00 :

FX3DH - R4 :

 

FX3DH - R2 :

 

FX3DH - A1 :

RS-485 COMM.
OPTION MODULE

1
2
3
4

TRX
TRX
SG

1
2
3
4

RXD
TXD
GND

1
2
3
4

SG

RS-232 COMM.
OPTION MODULE

4~20mA Output
OPTION MODULE

4~20mA
4~20mA

1

OUT1

FX3DH

OUT2

OUT1
OUT2

HTX20-FTS-502

DPR-TH1-ET

1 2 3 4 5 6 7 8 9 10 11

COM

NTC

POWER

OUT1                           OUT2

Humidity

TEMP

FX3DH

OPTIO

N

MO

DU

LE

c

L2

L1

AC100 - 240 V ~

50/60Hz

R

Vin

8(2)A, 250Vac

+5V

W(Y)

B

%

28

35

70

78

8

HTX20-FTS-502

dotech,inc

RH : 10~95%RH, 1.2~3.5V
T    :  NTC5K

RH & Temp Sensor

+5V
RH
GND
TH
TH

63

63

48

Sensor type  :  NTC 5K

Range  :  -50 ~ 105

Accuracy  :  ±0.3

 at 25

Sheath  :  

Φ

5 X 35mm, SUS

Cable  :  2C X 0.5mm

Φ

5

35

LEAD WIRE(2m)

SHRINK TUBE

SUS PIPE

OUT1

FX3DH

OUT2

HTX3515

27

25

12

2.5pie

6.7

Digital Temp. & Humidity  Controller (FX3DH SERIES)

Order Information

Basice Specification

FX3DH

PreCaution for Use

1. This product may cause an electric shock in handling. Please do not attempt to open it with 
   power turned on.
2. This product should be installed in a place fixed secured by a rack or panel.
3. This product can be used under the following environmental condition

   ① Indoor ② Pollution Degree ③ At an altitude of 2000m or below ④ Installation Category Ⅱ

4. To turn on or turn off power supply for this product, please the circuit breaker or switch of 
   a standard product of IEC 60947-1 or IEC 60947-3 product and install it within a close distance 
   allowing convenient operation by user.
5. Please be understood that if this product is dismantled or modified discretionary, 
   after sales service will not be able to be provided.
6. An output wire to be used for this product should be inflammable grade FV1 

   (V-1 grade or above), he thickness of the wire should be AWG No. 20 or above. (0.50㎟)

7. In order to prevent it from an inductive noise, please maintain the high-voltage wire and 
   power wire separated.
8. Please avoid installing the product in a place where a strong magnetism, noise, 
   severe vibration and impact exist.
9. When extending the sensor wire, use a shield wire and do not extend it unnecessary long.
10. The sensor wire and signal wire should be away from the power and load wires using 
     conduits separately installed.
11. Please avoid using the product near a device generating strong high frequency noise
     (high-frequency welding machine, high-frequency sewing machine, high-frequency 
     radiotelegraph, high capacity SCR controller)
12. Product’s damages other than those decribed in the guarantee conditions provided by 
     the manufacturer shall not be respoinsible by us.
13. Please use with being attached to a dual safety device in case of using for controlling instruments
     which could be effective to human life or property (eg: controlling atomic energy, medical 
     instruments, cars, trains, flights, burners, amusement instruments or safety machinery)

Power

AC100 - 240V ~ , 50/60Hz

Current

MAX 4VA

Model

Input / Output

Relay output 2p (OUT1,2 : 250Vac/8(2)A)

Humidity 1~4V Voltage input 1p. Temp.NTC 5K Thermistor input 1p

Operation

Temp. -10~50

 (No condensation only)

Storage

Temp. -20~60

, Humidity Under 90%RH

Sensor

HTX20-FTS-502 (Temp.& Humidity sensor of Voltage output type),  HTX3515

Display Range

-19.9~99.9

 : unit of 0.1

 / Other range : unit of 1

Connector

Screw Bolt Connector (1.5

㎟ 

 Wire Use Possibility)

Basic Model

RS-485 Comm. model (Comm. function MODBUS RTU MODE) 

RS-232 Comm. model (Install log printer, Trans text message) 

4~20mA Trans output model Connection cable is provided basically

Dimensions and Panel Cut-Out Form

 Comm. cable is provided basically

Unit 

Over

Over

DOTECH,INC

 l  http://www.dotech21.com

                                [email protected]

 

6F, JOONGANG-ILBO 778 Wonsi-Dong, Danwon-Gu, Ansan-Si,
Gyeonggi-Do, Korea TEL : +82-31-495-3767 / FAX : +82-31-495-3917

Connection Diagram

Accessory Information

Constitution (Function of Display Lamp and Button)

Turn on when output #1 is ON (Flickering at standby)

Turn on when output #2 is ON (Flickering at standby)

Display temp. value

ON at trip, Flickering at alarm

Use at program setup

Execute selected menu
 or Input setup value

Move between menus
 & Increase setup value

Move between menus
 & Decrease setup value

※ 

If pushing 

,

 at the same time, it displays the 1st decimal place for the current temp.

Option

Initializing setup value

If pushing for 10 sec. at the same time , setup value is initialized

※ The Aforementioned precautions must be observed, and if you fail to do so, 

    it may cause a product’s breakdown.

 COM : Signal input common terminal

 Vin : Humidity sensor input 

 NTC : Temperature sensor input 

 +5V : Humidity sensor power (5Vdc)

 OUT1 : Dehumidification/Humidification

             #1 ON/OFF output

 OUT2 : Dehumidification/Humidification 

             #2 ON/OFF output

Red : Humidity sensor power+5V
Yellow : Humidity measurement 
           signal output
Black : Humidity sensor power 0V 
white : Temperature sensor(NTC5K)
Blue : Temperature sensor(NTC5K)

Cable length
2M

Temp.& Humidity sensor (Humidity output 1~4V, Temp. output NTC5K)

Temperature Sensor (NTC5K) 

Humidity sensor (Humidity output 1~4V)

Humidity range: 0~100%RH
Humidity output 1~4Vdc
Connection Cable length 3M
1: Black : Humidity sensor power 0V 
2: Red : Humidity sensor power+5V
4: White : Humidity measurement 
              signal output

Humidity range: 0~100%RH
Temp. range: -

10~60℃

Humidity output 1~4Vdc
output NTC5K B3324K

Rev. 2011.01.13

Содержание FX3DH Series

Страница 1: ...ase use with being attached to a dual safety device in case of using for controlling instruments which could be effective to human life or property eg controlling atomic energy medical instruments cars trains flights burners amusement instruments or safety machinery Power AC100 240V 50 60Hz Current MAX 4VA Model Input Output Relay output 2p OUT1 2 250Vac 8 2 A Humidity 1 4V Voltage input 1p Temp N...

Страница 2: ... alarm Standard alarm operation without option Maintain alarm Maintain output ON after alarm occurs Standby alarm No output at initial operation until achieve the 1st setup value Execute both ALD ALC at the same time R4 Model OFF Output by temp ON Output by MV1 Output continuously regardless setup temp if manual output value is ON when manual output mode is ON Manual Output Value Output 1 R4 Model...

Страница 3: ...It outputs after setting delay time in spite of output condition During ON delay time output lamp is turned on with output after flickering in fast cycle 2 Min OFF Time It lets output not occur within min OFF time after it is turned off During min OFF time output lamp is turned on with output after it flickers every 1 second intervals 3 Min ON Time It is for avoiding frequent ON OFF of control out...

Страница 4: ...iation Control deviation is set up at DF in setting 1 group If DF value 0 it is always OFF Deviation High Low Limit Reverse Alarm Output is OFF when the deviation between PV value and SV value is higher or lower than setup value of control deviation Control deviation is set up at DF in setting 1 group If DF value 0 it is always OFF Absolute Value High Limit Alarm Output is ON when PV value is high...

Отзывы: