DOTECH FX3DH Series Скачать руководство пользователя страница 3

100 

101

102

0.1 

-19.9 

99.9 

2.0

P : 

 

PN :

0.1 

99.9 

1.0

ALA

ALB

ALC

ALD

OFF

C

H

AL1

AL2

AL3

AL4

AL5

AL6

SBA

104

Sec. 

999 

1

105

Sec. 

999 

5

106

Sec. 

999 

107
108
109

112
113

  / 

 

0N

  / 

0N

  / 

0N

:

:

:

:

 

1

 :

 

1

 

1

.

0

 :

 

 I

.

0

500

501

504

505

506

507

508

P

1

48

 : 4800BPS, 

96

 : 9600BPS,  

I92

 : 19200BPS, 

384

 : 38400BPS

1

128

  : 

 : 

509
510

511

513 

514 

0N

OFF

512 

OFF

OFF

PV   

 : 

 

 

                  

D IR

 : 

ReV

 : 

 

 

                       

ST1,ST2 

-

-

1

1

-199

-199

999

999

100

0

1

SEC 

0.1

0

5.0

1.0

SEC 

0.1

0.1

5.0

2.0

K

0.1

-19.9

99.9

0.0

0.1

0.1

-19.9

99.9

0.0

96

PV

H

111

110

-

1

U L  1~ 2

105

100

-

1

-50

U H  1~2

0

H

IN

H

T Y  1~ 2
D F  1~ 2
T P  1~ 2
D T  1~ 2
F T  1~ 2
N T  1~ 2
S F  1~ 2
H Y  1~ 2
A P  1~ 2
U H  1~ 2
U L  1~ 2
M D  1~ 2
M V  1~ 2

L O C

    D P
C O R
S F T
S D T
S T O
A D R
B D R

A O M

R T H
R T L

T C R

      I N

T

HT

HTD

Select Lock Function

Decimal Point Display

Correct PV (Present value)

Sensor Value Display Cycle

Communication Address (-R4 model)

Communication Speed (-R4 model)

Sensor Input Filter

Analogue Trans. Output(4~20mA) Mode (-A1 model)

Analogue Trans. Output (20mA) (-A1 model)

Analogue Trans. Output (4mA) (-A1 model)

SV(Set value)2 trans. mode

Setting 2 Group

Display Current Temp.

Push for

3 sec.

Push for
5 sec.

Select Control Type 

Control Deviation Value

Select Deviation Value

ON Delay Time (

1)

Minimum OFF Time (

2)

Minimum ON Time (

3)

Output at Sensor Error (

4)

Alarm Deviation Value

Alarm Option

Manual Output Mode Output (

5)

Manual Output Value Output (

6)

Setting 1 Group Table

 : 

General alarm

 : 

Maintain alarm

 : 

Standby alarm

 : 

Maintain & standby alarm

 : 

No use

 : Dehumidification

    (Cooling)mode

: Humidification

  (Heating)mode

 : 

Deviation high limit alarm

 : 

Deviation low limit alarm

 : 

Deviation high, low limit alarm

 : 

Deviation high, Low limit reverse alarm

 : 

Absolute value high limit alarm

 : 

Absolute value low limit alarm

 : 

Sensor open wire alarm

Setting 1 group loc

k

Setting 1, 2 group loc

k

Setting 1, 2group, temp. setup lock

,

Setting 2 Group Table

 

Select Lock Function

Sensor input mode

Correction of temperature sensor (

7)

Decimal Point(PV) Display (

8)

Correction of PV

Sensor Input Filter (

9)

Sensor Value Display Cycle

Lock cancel
Setting 1group
Setting 1, 2 group lock
Setting 1, 2group,

temp. setup lock

Correct the accuracy of sensor
e.g) If displayed humidity is 19% and I/O 
humidity is 18%, it is corrected by inputting -1.0%

Display 1st decimal place

Display computing of 1/10

Select decimal point display method

In case of frequent hunting of the present value,
it is corrected by increasing filter value.

Set the current temp. display cycle.

Set communication address.

Set communication speed

Set max. value. of analogue transmission output (20mA)

Set min. value. of analogue transmission output (4mA)

Output #1 

Output #2 

Output #3 

Output #4 

Common

&

Individual

setup

1) ON delay time : It outputs after setting delay time in spite of output condition. During ON delay time, output lamp is turned on with output after flickering in fast cycle
2) Min OFF Time : It lets output not occur within min. OFF time after it is turned off. During min. OFF time, output lamp is turned on with output after it flickers every 1 second intervals
3) Min ON Time : It is for avoiding frequent ON/OFF of control output and maintains ON condition in spite of OFF condition during Min ON Time after being turned on. (In case of sensor error, OFF at once)
4) Output at Sensor Error : In case of sensor error such as open wire/short, it sets ON/OFF status of the related output.
5) Manual Output Mode : OFF : Output by  PV  / ON : Output by 

MVI 

(-R4 model)

PV(Current value) trans. mode

SV(Set value)1 trans. mode

Humidification(Heating) proportional Control
Dehumidification(Cooling) proportional Control

+Deviation

±Deviation

Setup Value Step Control.

Input SV1(Set Value1) and SV2(Set Value2) separately.
Only input SV1(Set Value1), then SV2(Set Value2) 

automatically will be input.

SV1(Set Value1) -> SV2(Set Value2)

7) Correction of temperature sensor: It is displayed when sensor input mode(IN) set to Temperature & Humidity control mode or humidity control and temperature display mode.

9) Sensor Input Filter Value : It avoids hunting by giving temperature measuring delay.

Analogue Trans. Output (20mA) (-A1 model)

Analogue Trans. Output (4mA) (-A1 model)

Analogue Trans. Output(4~20mA) Mode
(-A1 model)

Communication Address (-R4 model)

Communication Speed (-R4 model)

PV Trans.

SV1,2(Set value) Trans.

Dehumidification(Cooling) 

proportional Control

Humidification(Heating) 

proportional Control

Individual SV(Set value) mode

Set Value(SV) Unification Mode

Unifying SV(Set value) Mode

6) Manual Output Value Setup : It outputs continuously regardless of PV. if manual output value is ON when manual output mode is ON. (-R4 model)



Lock  cancel

STEP

UNIT

CODE

DESCRIPTION

NO

MIN

MAX

DEFAULT

USER SETUP

STEP

UNIT

CODE

DESCRIPTION

NO

MIN

MAX

DEFAULT

USER SETUP

Essential parameter for operation

The second parameter for optimal operation

Essential parameter for operation

The second parameter for optimal operation

Sensor input mode

Use for humidity only
Use for tempeature only
Use for humidity and temperature control
Use for humidity control and 

temperature display

Correct PV (Temperature value)

It is only displayed in case of displaying both 

humidity and temperature,  correct the accuracy 

of the temp. sensor

e.g) If displayed temp. is 19

 and I/O temp is 

18

, it is corrected by inputting -1.0

High limit by user setup

Low limit by user setup

8) PV Decimal Point Display : In case of setting as ‘1’, it displays the current value with cutting the decimal place.

Use for humidity 

control only

Use for temp.

control only 

Use for humidity and 

temperature control

Use for humidity control 

and temperature display

Содержание FX3DH Series

Страница 1: ...ase use with being attached to a dual safety device in case of using for controlling instruments which could be effective to human life or property eg controlling atomic energy medical instruments cars trains flights burners amusement instruments or safety machinery Power AC100 240V 50 60Hz Current MAX 4VA Model Input Output Relay output 2p OUT1 2 250Vac 8 2 A Humidity 1 4V Voltage input 1p Temp N...

Страница 2: ... alarm Standard alarm operation without option Maintain alarm Maintain output ON after alarm occurs Standby alarm No output at initial operation until achieve the 1st setup value Execute both ALD ALC at the same time R4 Model OFF Output by temp ON Output by MV1 Output continuously regardless setup temp if manual output value is ON when manual output mode is ON Manual Output Value Output 1 R4 Model...

Страница 3: ...It outputs after setting delay time in spite of output condition During ON delay time output lamp is turned on with output after flickering in fast cycle 2 Min OFF Time It lets output not occur within min OFF time after it is turned off During min OFF time output lamp is turned on with output after it flickers every 1 second intervals 3 Min ON Time It is for avoiding frequent ON OFF of control out...

Страница 4: ...iation Control deviation is set up at DF in setting 1 group If DF value 0 it is always OFF Deviation High Low Limit Reverse Alarm Output is OFF when the deviation between PV value and SV value is higher or lower than setup value of control deviation Control deviation is set up at DF in setting 1 group If DF value 0 it is always OFF Absolute Value High Limit Alarm Output is ON when PV value is high...

Отзывы: