100
101
102
K
0.1
-19.9
99.9
2.0
P :
PN :
K
0.1
0
99.9
1.0
ALA
ALB
ALC
ALD
OFF
C
H
AL1
AL2
AL3
AL4
AL5
AL6
SBA
104
Sec.
1
0
999
1
105
Sec.
1
0
999
5
106
Sec.
1
0
999
5
107
108
109
112
113
/
0N
/
0N
/
0N
:
:
:
:
1
:
1
1
.
0
:
I
.
0
500
501
504
505
506
507
508
P
-
1
48
: 4800BPS,
96
: 9600BPS,
I92
: 19200BPS,
384
: 38400BPS
1
128
:
:
509
510
511
513
514
0N
OFF
512
OFF
OFF
PV
:
D IR
:
ReV
:
ST1,ST2
:
-
-
1
1
-199
-199
999
999
100
0
1
SEC
0.1
0
5.0
1.0
SEC
0.1
0.1
5.0
2.0
K
0.1
-19.9
99.9
0.0
0.1
℃
0.1
-19.9
99.9
0.0
96
PV
H
111
110
-
1
U L 1~ 2
105
100
-
1
-50
U H 1~2
0
H
IN
H
T Y 1~ 2
D F 1~ 2
T P 1~ 2
D T 1~ 2
F T 1~ 2
N T 1~ 2
S F 1~ 2
H Y 1~ 2
A P 1~ 2
U H 1~ 2
U L 1~ 2
M D 1~ 2
M V 1~ 2
L O C
D P
C O R
S F T
S D T
S T O
A D R
B D R
A O M
R T H
R T L
T C R
I N
T
HT
HTD
Select Lock Function
Decimal Point Display
Correct PV (Present value)
Sensor Value Display Cycle
Communication Address (-R4 model)
Communication Speed (-R4 model)
Sensor Input Filter
Analogue Trans. Output(4~20mA) Mode (-A1 model)
Analogue Trans. Output (20mA) (-A1 model)
Analogue Trans. Output (4mA) (-A1 model)
SV(Set value)2 trans. mode
Setting 2 Group
Display Current Temp.
Push for
3 sec.
Push for
5 sec.
Select Control Type
Control Deviation Value
Select Deviation Value
ON Delay Time (
※
1)
Minimum OFF Time (
※
2)
Minimum ON Time (
※
3)
Output at Sensor Error (
※
4)
Alarm Deviation Value
Alarm Option
Manual Output Mode Output (
※
5)
Manual Output Value Output (
※
6)
Setting 1 Group Table
:
General alarm
:
Maintain alarm
:
Standby alarm
:
Maintain & standby alarm
:
No use
: Dehumidification
(Cooling)mode
: Humidification
(Heating)mode
:
Deviation high limit alarm
:
Deviation low limit alarm
:
Deviation high, low limit alarm
:
Deviation high, Low limit reverse alarm
:
Absolute value high limit alarm
:
Absolute value low limit alarm
:
Sensor open wire alarm
Setting 1 group loc
k
Setting 1, 2 group loc
k
Setting 1, 2group, temp. setup lock
,
Setting 2 Group Table
Select Lock Function
Sensor input mode
Correction of temperature sensor (
※
7)
Decimal Point(PV) Display (
※
8)
Correction of PV
Sensor Input Filter (
※
9)
Sensor Value Display Cycle
Lock cancel
Setting 1group
Setting 1, 2 group lock
Setting 1, 2group,
temp. setup lock
Correct the accuracy of sensor
e.g) If displayed humidity is 19% and I/O
humidity is 18%, it is corrected by inputting -1.0%
Display 1st decimal place
Display computing of 1/10
Select decimal point display method
In case of frequent hunting of the present value,
it is corrected by increasing filter value.
Set the current temp. display cycle.
Set communication address.
Set communication speed
Set max. value. of analogue transmission output (20mA)
Set min. value. of analogue transmission output (4mA)
Output #1
Output #2
Output #3
Output #4
Common
&
Individual
setup
1) ON delay time : It outputs after setting delay time in spite of output condition. During ON delay time, output lamp is turned on with output after flickering in fast cycle
2) Min OFF Time : It lets output not occur within min. OFF time after it is turned off. During min. OFF time, output lamp is turned on with output after it flickers every 1 second intervals
3) Min ON Time : It is for avoiding frequent ON/OFF of control output and maintains ON condition in spite of OFF condition during Min ON Time after being turned on. (In case of sensor error, OFF at once)
4) Output at Sensor Error : In case of sensor error such as open wire/short, it sets ON/OFF status of the related output.
5) Manual Output Mode : OFF : Output by PV / ON : Output by
MVI
(-R4 model)
PV(Current value) trans. mode
SV(Set value)1 trans. mode
Humidification(Heating) proportional Control
Dehumidification(Cooling) proportional Control
+Deviation
±Deviation
Setup Value Step Control.
Input SV1(Set Value1) and SV2(Set Value2) separately.
Only input SV1(Set Value1), then SV2(Set Value2)
automatically will be input.
SV1(Set Value1) -> SV2(Set Value2)
7) Correction of temperature sensor: It is displayed when sensor input mode(IN) set to Temperature & Humidity control mode or humidity control and temperature display mode.
9) Sensor Input Filter Value : It avoids hunting by giving temperature measuring delay.
Analogue Trans. Output (20mA) (-A1 model)
Analogue Trans. Output (4mA) (-A1 model)
Analogue Trans. Output(4~20mA) Mode
(-A1 model)
Communication Address (-R4 model)
Communication Speed (-R4 model)
PV Trans.
SV1,2(Set value) Trans.
Dehumidification(Cooling)
proportional Control
Humidification(Heating)
proportional Control
Individual SV(Set value) mode
Set Value(SV) Unification Mode
Unifying SV(Set value) Mode
6) Manual Output Value Setup : It outputs continuously regardless of PV. if manual output value is ON when manual output mode is ON. (-R4 model)
※
※
※
※
※
※
※
※
※
Lock cancel
STEP
UNIT
CODE
DESCRIPTION
NO
MIN
MAX
DEFAULT
USER SETUP
STEP
UNIT
CODE
DESCRIPTION
NO
MIN
MAX
DEFAULT
USER SETUP
Essential parameter for operation
The second parameter for optimal operation
Essential parameter for operation
The second parameter for optimal operation
Sensor input mode
Use for humidity only
Use for tempeature only
Use for humidity and temperature control
Use for humidity control and
temperature display
Correct PV (Temperature value)
It is only displayed in case of displaying both
humidity and temperature, correct the accuracy
of the temp. sensor
e.g) If displayed temp. is 19
℃
and I/O temp is
18
℃
, it is corrected by inputting -1.0
℃
High limit by user setup
Low limit by user setup
8) PV Decimal Point Display : In case of setting as ‘1’, it displays the current value with cutting the decimal place.
Use for humidity
control only
Use for temp.
control only
Use for humidity and
temperature control
Use for humidity control
and temperature display