Appendix B Alarm/monitor data
A-25
B.2 List of Inverter alarms
CNC
code
Drive
code
Item
CNC
code
Drive
Description
2
0x02
EEPROM data error
97
0x61
C-phase signal detection failure
2
0x02
Flash memory error
98
0x62
C-phase signal width failure
3
0x03
Main circuit detecting element
error
99
0x63
Error with pulse count per rotation
when encoder is used
3
0x03
CNV main circuit detecting
element error
99
0x63
Error with pulse count per rotation
when magnetmetric sensor is used
4
0x04
Parameter setting error
99
0x63
Encoder pulse count error
5
0x05
Motor/Servo capacity unmatched
100
0x64
Position-detecting signal wire break
6
0x06
DPRAM error
101
0x65
INC signal error when encoder is
used
16
0x10
Over current
(Short-circuit current)
101
0x65
INC signal error when
magnetmetric sensor is used
17
0x11
Ground fault
102
0x66
Magnetmetric sensor signal
detection error
18
0x12
Carrier frequency error
103
0x67
Magnetmetric sensor signal wire
break.
19
0x13
On-delay error
104
0x68
Orientation card unmatched
20
0x14
Motor over current
105
0x69
Winding change-over failure
32
0x20
Fuse blow-out
106
0x6A
Initial zero point loading error
33
0x21
MC operation failure
107
0x6B
Emergency stop operation failure
48
0x30
Regeneration error
113
0x71
Over-load (Momentary max. load)
50
0x32
Regeneration over-load warning
114
0x72
Over-load (Max. continuous load)
50
0x32
Regeneration over-load warning
115
0x73
DB over-load
51
0x33
Main power wiring error
116
0x74
Inrush current resistance over-load
52
0x34
Converter regeneration over-
current
117
0x75
Control panel temperature rise to 60
℃
64
0x40
Over-voltage
117
0x75
Internal cooling fan error
64
0x40
CNV over-voltage
117
0x75
Load error
65
0x41
Low-voltage
121
0x79
Motor over-heat
65
0x41
CNV low-voltage
121
0x79
Motor thermistor wire break
66
0x42
Initial charge error
122
0x7A
Heat sink over-heat
67
0x43
Control circuit low-voltage
122
0x7A
Fin temperature rise for more than 1
minute
81
0x51
Over-speed (at motor)
122
0x7A
Heat sink thermistor wire break
82
0x52
Over-speed (at machine)
129
0x81
PG back-up error
83
0x53
Excessive speed deviation
130
0x82
PG sum check error
84
0x54
Over-speed (at low-speed
winding motor)
131
0x83
PG battery error
85
Ox55
Over-speed (C-axis)
132
0x84
PG absolute error
96
0x60
Tune-up incomplete when
encoder is used
133
0x85
PG over-speed
96
0x60
Tune-up incomplete when
magnetmetric sensor is used
134
0x86
PG over-heat
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...