14.1.7 Maximum number of motor revolutions
14-30
14.1.7 Maximum number of motor revolutions
CNC setting
• MD32250 RATED_OUTVAL [0] (For each axis) ##
Meaning:
Ratio of speed reference to maximum number of motor revolutions
Standard setting value: 100 [%]
• MD32260 RATED_VELO [0] (For each axis)
Meaning:
Maximum number of motor revolutions
Setting value: To be set to maximum number of motor revolutions (the number of revo-
lutions [min
-1
] under maximum command value)
Assign the value of MD880.
Note: In the case of a Servo drive, the parameter is to be set to specified
maximum number of motor revolutions
×
1.2 (Over-speed alarm
detection speed).
Drive setting
Settings of Servo axis and Spindle drives in common
• MD880 NORMALIZATION_OVER_PROFIBUS (For each axis)
Meaning:
The number of motor revolutions under maximum speed reference
(ox40000000) at PROFIBUS.
Setting value: Setting this parameter is prohibited because it is automatically set to
internal drive data.
CNC creates a value equivalent to MD32260 using this parameter if [min
-
1
] and MD32250 = 0.
Servo drive
No related parameter exists. Maximum number of motor revolutions is automatically read
from a motor encoder and set. The setting value multiplied by 1.2 is displayed at MD880.
Spindle drive
• MD6500 (Cn500) RATED_SPEED_SETTING (For each axis)
Meaning: Rated
speed
Setting value: [min
-1
]
The value of this parameter is also displayed at MD880.
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...