Appendix A Parameters
A-19
6979
Cn8BF
7
0
250
None
Position window 1
1st positioning completion width
6980
Cn8C0
7
0
250
None
Position window 2
2nd positioning completion width
6981
Cn8C1
7
0
250
None
Position window 3
3rd positioning completion width
6988
Cn8C8
0x0000
0x0000
0xFFFF
None
Reserved for user 0F
Reserved for user 0F
7018
Cn8E6
0x0000
0x0000
0xFFFF
None
Alarm Mask
Alarm mask
7019
Cn8E7
0x0000
0x0000
0xFFFF
None
System Switch
System switch
7046
Cn902
0
3000
15000
None
PWN Frequency
PWM frequency
7047
Cn903
(0 << 8)
+ 0
(0 << 8)
+ 0
(255 <<
8) + 30
None
On Delay Time and Comp
Lower byte: On-delay time; upper
byte: On-delay compensation
constant
7050
Cn906
0xACA3
0
65535
None
AD Parameter 1
A/D detection-setting parameter 1
7059
Cn90F
0
-32768
32767
None
Current Det Zero Adj U
Current detection zero adjustment
(U-phase)
7060
Cn910
0
-32768
32767
None
Current Det Zero Adj V
Current detection zero adjustment
(V-phase)
7061
Cn911
0
-32768
32767
None
Current Det Gain Adj UV
Current detection gain adjustment
(U and V-phases)
7068
Cn918
0x0000
0x0000
0x00FF
None
PG Power Voltage Zero Adj Lower byte: PG power voltage
adjustment
Upper byte: Not used
7074
Cn91E
0
0
0xFFFF
None
Standalone Flag
Stand-alone switch
7075
Cn91F
0x0000
0x0000
0xFFFF
None
MotorTyp PowerVolt
EncTyp
Motor type (8-bit)
Input voltage (4 bits)
Encoder type (4 bits)
7076
Cn920
0x0000
0x0000
0xFFFF
None
Encorder Soft Version
Encoder software version
7077
Cn921
0
0
65535
None
Motor Size
Motor capacity
CNC
paramete
r number
Drive
parameter
number
Initial
value
Lower
limit
Upper
limit
Unit
Display name
Description
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...