Maintenance and Check
16.3.1 Replacing a battery in the Absolute encoder
16-8
16.3 Absolute encoder
16.3.1 Replacing a battery in the Absolute encoder
If the voltage of the Absolute encoder battery decreases to 2.7V or less, the SERVOPACK
issues a "Battery warning (A.93)".
Replace the battery in the following procedure. For the recommended Absolute encoder bat-
teries, refer to 16.3.2 "Handling a battery".
Procedure to replace a battery
1. Replace the battery with SERVOPACK control power turned on.
2. The "Battery warning (A.93)" will be released automatically after the battery has been
replaced.
3. Verify that the encoder works correctly. This completes the battery replacement.
If the battery is disconnected (the encoder cable is disconnected) with the SERVOPACK control power
turned off, the Absolute encoder data is cleared and you will have to set up the Absolute encoder again.
Refer to 16.3.3 "Setting up (Initializing) Absolute encoder".
16.3.2 Handling a battery
In order for the Absolute encoder to hold the position information even while the power is
turned off, a back-up battery is required. We recommend the following battery for this pur-
pose.
Type: ER6VC3 (Lithium battery)
3.6 V 2000 mAH
Toshiba Battery
IMPORTANT
Converter
Battery
compartment
Battery
connecter
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...