14.4 High-speed High-accuracy Cutting
14-101
Fine interpolation
DP cycle period interpolation is enabled for the position interpolated by IPO cycle period,
when the interpolation position command is transferred from IPO cycle to DP cycle (Section
14.1.1).
There are two types of interpolation: difference interpolation (linear interpolation) and C
spline interpolation (curvilinear interpolation).
Typically employ the C spline interpolation.
• MD33000 FIPO_TYPE
Meaning:
Fine interpolation type
Setting value: 1---Differential interpolation
2---C spline interpolation
(setting value for compatibility with conventional versions)
3---C spline interpolation
Standard setting value: 3
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...