13.2 Specification of machine data and parameters
13-5
MD10000 AXCONF_MACHAX_NAME_TAB [0] (1st axis)
MD10000 AXCONF_MACHAX_NAME_TAB [1] (2nd axis)
The array structure is used not only for the axis setting but also for differentiating items that are of the
same type but are used for different applications--for example, differentiating between motor encoder
and external encoder, and representing gear numbers and parameter set numbers.
About “digit” setting
Especially, some Servo drive parameters (MD3000 or greater) are set in hexadecimal digits.
As shown in the following example, a digit is either of the 4 hexadecimal digits of a param-
eter. Each parameter digit is to be set to a value from 0 to 15 (0-FH in hexadecimal notation).
The digits are numbered from 0 to 3.
If it is specified to set parameters in digits, set the digit one by one as shown in the example,
paying attention not to confuse the digits.
About unit data
If different machine data units are used for linear axis and rotary axis in 840DI, take care
that setting values may be displayed in different units.
In 840DI system, generally, machine data having fractional portion can be displayed or
entered without the frictional portion removed off.
MD10230 [9] SCALING_FACTOR_USER_DEF [9] (Common to all axes)
Meaning: Setting unit of position loop gain
Setting value: 1.0 [1/S]
EXAMPLE
INFO
MD3000= 0 F 1 0 (Hex)
Digit0 (0-F)
Digit1 (0-F)
Digit2 (0-F)
Digit3 (0-F)
INFO
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...