Drive set-up procedure
14.2.8 Predictive control
14-46
Servo drive settings
For cutting feed
• MD3079 digit 0 (Pn131 digit 0) SWITCH_PREDICTED_1
Meaning:
1st predictive control switch
Setting value: 0 --- Disabled
1 --- Enabled (Tp = 0.001)
2 --- Enabled (Tp = 0.002)
• MD3038 (Pn132) PARAM_C_PREDICTED_1
Meaning:
1st predictive control parameter C
Setting value: [0.01]
• MD3081 (Pn133) PARAM_CD_PREDICTED_1
Meaning:
1st predictive control parameter Cd
Setting value: [0.01]
• MD3082 (Pn132) PARAM_ALPHA_PREDICTED_1
Meaning:
1st predictive control parameter
α
Setting value: [0.01]
• MD3083 (Pn135) EQUIV_KP_ADJ_PREDICTED_1
Meaning:
1st predictive control equivalent Kp fine adjustment amount
Setting value: [0.1/s]
• MD3084 (Pn136) SPD_FF_GAIN_PREDICTED_1
Meaning:
1st predictive control speed FF gain
(Added to predictive feed forward control.)
Setting value: [%]
• MD3085 (Pn137) TRQ_FF_GAIN_PREDICTED_1
Meaning:
1st predictive control torque FF gain
(Added to predictive feed forward control.)
Setting value: [%]
• MD3086 (Pn138) TRQ_FF_FIL_T_CONST_PREDIC_1
Meaning:
1st predictive control torque FF filter time constant
(Added to predictive feed forward control.)
Setting value: [0.01 ms]
For positioning
• MD3079 digit 1 (Pn131 digit 1) SWITCH_PREDICTED_1
Meaning:
2nd predictive control switch
Setting value: 0 --- Disabled
1 --- Enabled (Tp = 0.001)
2 --- Enabled (Tp = 0.002)
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...