14.1 Fundamental settings
14-35
When alarm "41" is issued at X1 axis and then alarm "255" is
issued at Y1 axis
Since this information is transmitted from the drive to the CNC through a low-speed mes-
sage line, the alarm indication at CNC has a few-minute delay from the alarm-issued time.
However, the alarm time counter shows a precise time.
Drive Digital operator display
Alarm for an axis selected by the Digital operator is displayed as follows:
Example: A.51 --- Alarm "51" (a "Drive code" in the Alarm list) is issued at a drive selected.
• Alarm code for a drive is displayed in decimal number on the CNC screen, while it is displayed in
hexadecimal number on the Digital operator.
• For drive alarm codes, refer to Appendix B.1 "List of Servo unit alarms" and Appendix B.2 "List
of Inverter alarms".
Alarm time counter (in ms)
Alarm group code
Alarm-issuing axis name
CNC alarm code (Drive-related alarm load in common)
380500: PROFIBUS DP: Drive X1, Code 41, Value 0, Time 524112
380500: PROFIBUS DP: Drive Y1, Code 255, Value 0, Time 524112
INFO
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...