Drive data list
A.1 Servo unit parameter list
A-4
3090
Pn13C
0
-10000
10000
0.1/s
Equiv Kp Adj Predicted 2
2nd predictive control equivalent Kp
fine adjustment amount
3091
Pn13D
0
0
100
%
Spd FF Gain Predicted 2
2nd predictive control speed FF gain
3092
Pn13E
0
0
100
%
Trq FF Gain Predicted 2
2nd predictive control torque FF gain
3093
Pn13F
0
0
65535
0.01ms
Trq FF Fil T Const
Predic 2
2nd predictive control torque FF filter
time constant
3094
Pn140
800
0
1000
0.01
Param C Predicted 3
3rd predictive control parameter C
3095
Pn141
0
0
1000
0.01
Param Cd Predicted 3
3rd predictive control parameter Cd
3096
Pn142
0
-90
1000
0.01
Param Alpha Predicted 3
3rd predictive control parameter
α
3097
Pn143
0
-10000
10000
0.1/s
Equiv Kp Adj Predicted 3
3rd predictive control equivalent Kp
fine adjustment amount
3098
Pn144
0
0
100
%
Spd FF Gain Predicted 3
3rd predictive control speed FF gain
3099
Pn145
0
0
100
%
Trq FF Gain Predicted 3
3rd predictive control torque FF gain
3100
Pn146
0
0
65535
0.01ms
Trq FF Fil T Const
Predic 3
3rd predictive control torque FF filter
time constant
3101
Pn147
10000
0
65535
None
1st P Gain Quad Err Comp 1st-stage positive quadrant error
compensation gain
3102
Pn148
0
0
30000
0.01%
1st P Lmt Ofs Quad Err
Comp
1st-stage positive quadrant error
compensation limit offset
3103
Pn149
1000
0
65535
None
2nd P Gain Quad Err
Comp
2nd-stage positive quadrant error
compensation gain
3104
Pn14A
0
0
30000
0.01%
2nd P Lmt Ofs Quad Err
Comp
2nd-stage positive quadrant error
compensation limit
3105
Pn14B
0
-30000
30000
0.01%
P Lmt Adj Quad Err Comp Positive quadrant error compensation
limit fluctuation
3106
Pn14C
0
0
30000
0.01%
P Lmt Clamp Quad Err
Comp
Positive quadrant error compensation
limit clamp value
3107
Pn14D
10000
0
65535
None
1st N Gain Quad Err
Comp
1st-stage negative quadrant error
compensation gain
3108
Pn14E
0
0
30000
0.01%
1st N Lmt Ofs Quad Err
Comp
1st-stage negative quadrant error
compensation limit offset
3109
Pn14F
1000
0
65535
None
2nd N Gain Quad Err
Comp
2nd-stage negative quadrant error
compensation gain
3110
Pn150
0
0
30000
0.01%
2nd N Lmt Ofs Quad Err
Comp
2nd-stage negative quadrant error
compensation limit
3111
Pn151
0
-30000
30000
0.01%/ms N Lmt Adj Quad Err
Comp
Negative quadrant error compensation
limit fluctuation
3112
Pn152
0
0
30000
0.01%
N Lmt Clamp Quad Err
Comp
Negative quadrant error compensation
limit clamp value
3113
Pn153
0
-350
1600
0.1/s
Timing Const Quad Err
Comp
Quadrant error compensation timing
constant
3114
Pn154
100
10
100
%
Damp Ratio AntiVib on
STP
Stop vibration suppression attenuation
ratio
3115
Pn155
1024
0
32767
ms
Start Time AntiVib on STP Stop vibration suppression start time
3116
Pn156
0
0
65535
0.01ms
Scale Ovrsht Ctrl Tim
Const
Scale overshoot suppression time
constant
3200
Pn200
0x0100 0x0000
0x0300
None
Switch Position Control
Position control command type
selection switch
3201
Pn201
16384
16
16384
pulse/rev
PG Divider
PG dividing ratio
CNC
parameter
number
Drive
parameter
number
Initial
value
Lower
limit
Upper
limit
Unit
Display name
Description
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...