Drive set-up procedure
14.2.2 Speed control
14-38
14.2.2 Speed control
The following explains how to set fundamental drive parameters for speed control.
Servo drive
• MD3030 (Pn100) KV (For each axis)
Meaning:
Speed loop gain
Setting value: [0.1 Hz]
To express the setting value in previous unit [1/s], multiply the value by
2
π
/10.
• MD3031 (Pn101) KVI (For each axis)
Meaning:
Speed loop integration time constant
Setting value: [0.01 ms]
• MD3033 (Pn103) LOAD_INERTIA_RATIO
Meaning:
Load inertia ratio to motor inertia
Setting value: [%]
• MD3041 digit 1 (Pn10B digit 1) GAIN_SWITCH (For each axis) ##
Meaning:
Switching between PI control and IP control
Setting value: 0 --- PI control is applied to speed control.
1 --- IP control is applied to speed control.
Standard setting value: 1
• MD3351 (Pn401) TIME_CONST_TRQ_REF_FILTER (For each axis)
Meaning:
1st-stage torque reference filter time constant
Setting value: [0.01 ms]
• MD3363 (Pn40D) TORQUE_FILTER_CONSTANT_2 (For each axis)
Meaning:
2nd-stage torque reference filter time constant
Setting value: [0.01 ms]
• MD3364 (Pn40E) TORQUE_FILTER_CONSTANT_3 (For each axis)
Meaning:
3rd stage torque reference filter time constant
Setting value: [0.001 ms]
Spindle drive
• MD6060 (Cn060) ASR_P_GAIN_H_I (For each axis)
Meaning:
Speed control proportional gain (H gear)
Setting value: [0.1%/Hz]
• MD6061 (Cn061) ASR_I_TIME_H_I (For each axis)
Meaning:
Speed control integration time (H gear)
Setting value: [0.1 ms]
• MD6062 (Cn062) ASR_P_GAIN_M_L_I (For each axis)
Meaning:
Speed control proportional gain (M and L gears)
Setting value: [0.1%/Hz]
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...