How to use Digital Operation
12.2.3 Checking the motor type
12-20
12.2.3 Checking the motor type
This display mode is used for maintenance of the motor. When the user constant Fn011 is
set, this mode becomes the motor type checking mode. In addition, when the SERVOPACK
is a special specification item, you can check its specification number.
To check the motor type, use the following procedure.
1. On the axis selection mode, select the axis you want to operate.
2. Press the [DSPL/SET] key and select the auxiliary function execution mode.
3. Select the user constant Fn011. Press the [LEFT] or [RIGHT] key to select the setting
digit.
Press the [UP] or [DOWN] key until the value you want to set is displayed.
4. Press the [DATA/ENTER] key to view the servo motor type and voltage identification
data.
5. Press the [DSPL/SET] key to view the capacity of servo motor.
Servo motor type
Voltage
Data
Servo motor type
Data
Voltage
00
SGMAH
00
100 VAC or 140 VDC
01
SGMPH
01
200 VAC or 280 VDC
02
SGMSH
02
Reserved
03
SGMGH-
□
A (1500 min
-1
)
04
SGMGH-
□
B (1000 min
-1
)
05
SGMDH
06
SGMUH
07
SGMKS
The capacity is the indication multiplied by 10 [W].
The example on the left shows 100 W.
servo motor type
voltage
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...