Drive data list
A.3 List of Inverter parameter
A-16
6605
Cn605
3000
0
20000
0.1msec
Serch Pole Pre Count
Initial magnetic pole detection
estimated time
6606
Cn606
100
1
20000
0.1msec
Serch Pole Level
Initial magnetic pole detection
control time
6607
Cn607
200
1
1000
0.1%
Serch Pole Torque Limit
Initial magnetic pole detection torque
limit
6608
Cn608
1
0
1
None
Serch Enc Phase C Select
C-phase detection selection
6700
Cn700
1500
10
60000
min
-1
Base Speed 1
H winding base speed
6701
Cn701
3500
10
60000
min
-1
Max Output Decrease
Start 1
H winding max. output reduction
starting point
6702
Cn702
3500
10
60000
min
-1
Rated Speed 1
H winding constant output speed
6703
Cn703
3500
100
65000
min
-1
Maximum Speed 1
H winding motor max. speed
6704
Cn704
22
1
750
0.1Kw
Continuous Rated Output 1
H winding continuous rated output
6706
Cn706
44
1
1500
0.1Kw
Max Output 1
H winding max. output
6707
Cn707
44
1
1500
0.1Kw
Max Output Dec 1
H winding max. output reduction 1
6710
Cn710
44
1
1500
0.1Kw
Max Output Dec A1
H winding max. output reduction A1
6711
Cn711
169
0
4000
0.01Hz
Motor Rated Slip 1
H winding rated slip frequency
6712
Cn712
134
10
4000
0.1A
Motor Rated Current 1
H winding motor secondary current
6713
Cn713
135
10
2000
0.1A
Motor No-load Current 1
H winding rated exciting current
reference
6714
Cn714
80
0
500
V
Base Voltage 1
H winding motor no-load voltage
6715
Cn715
100
0
250
0.01
Motor Iron Sat Coeff A1
H winding exciting current
correction coefficient A
6716
Cn716
100
0
250
0.01
Motor Iron Sat Coeff B1
H winding exciting current
correction coefficient B
6717
Cn717
0
0
200
0.1%
Base Iron Loss 1
H winding base core-loss current
6718
Cn718
0
0
200
0.1%
Max Iron Loss 2
H winding max. number of
revolutions core-loss current
6719
Cn719
50
0
600
0.01
Ω
ACR P Gain A1
H winding ACR gain A
6720
Cn720
50
0
600
0.01
Ω
ACR P Gain B1
H winding ACR gain B
6721
Cn721
50
0
600
0.01
Ω
ACR P Gain C1
H winding ACR gain C
6722
Cn722
50
0
600
0.01
Ω
ACR P Gain D1
H winding ACR gain D
6723
Cn723
200
0
1000
0.01msec
ACR Time Constant 1
H winding ACR time constant
6724
Cn724
100
0
200
%
Mgnetiging Current Limit 1 H winding exciting current limiter
6729
Cn729
120
100
150
%
Motor Accel Level 1
H winding motor overspeed level
6736
Cn736
1000
0
65000
0.0001
Ω
Term Resistance 1
H winding motor line resistance
6737
Cn737
500
0
60000
0.001mH
Leak Inductance d1
H winding d-axis inductance
6738
Cn738
500
0
60000
0.001mH
Leak Inductance q2
H winding q-axis inductance
6739
Cn739
0
0
250
%
Magnetiging Current 1
H winding weakening magnetic field
current
6740
Cn740
1000
0
10000
0.1Hz
Base Frequency
V/F Base frequency
6741
Cn741
500
0
10000
0.1Hz
Mid Output Frequency
V/F intermediate frequency
6742
Cn742
130
0
5000
0.1V
Mid Output Frequency Volt
V/F intermediate output frequency
voltage
6743
Cn743
5
0
10000
0.1Hz
Min Output Frequency
V/F min. output frequency
CNC
paramete
r number
Drive
parameter
number
Initial
value
Lower
limit
Upper
limit
Unit
Display name
Description
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...