M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
694
IB-1501279-H
16.29 Safety Axis Parameters
Set the axis to be outside the scope of smart safety observation.
0 : Enable smart safety observation
1 : Disable smart safety observation
(Note) The settings of "#51101 SF_Disable" and "#51301 SF_SDisable" must be the same within a multi-
hybrid drive unit.
Select which of the safe stop methods to use when an error is detected in the smart safety observation.
0 : STO
1 : SS1
Specify the upper limits of machine-end speed determined as safe for each of SLS speed tolerances 1 to 4.
If the SLS detection delay time has elapsed with the command/FB speed exceeding the safely-limited speed
while SLS is ON, a safe stop (SS1 or STO) is executed. The safely-limited speed to be applied to SLS is
calculated using the following equation.
Safely-limited speed = SLS speed tolerance x SLS speed override / 100
---Setting range---
0 to 999999 (mm/min or °/min)
Specify the speed overrides 1 to 16 with respect to SLS speed tolerances 1 to 4.
For details refer to SLS speed tolerances 1 to 4.
---Setting range---
0 to 100 (%)
Specify the speed clamp ratio that is applied while SLS is ON.
Set the ratio to about 80 to 90%. While SLS is ON, the command speed is clamped at the following speed:
Clamp speed = Safely-limited speed x SLS speed clamp ratio / 100
(Safely-limited speed = SLS speed tolerance x SLS speed override / 100)
---Setting range---
0 to 100 (%)
Specify a period of time to detect a speed error while SLS is ON. A safe stop (SS1 or STO) is executed if the
period of time set in this parameter has elapsed with the command/FB speed exceeding the safely-limited
speed.
---Setting range---
0 to 9999 (ms)
Specify a period of time to detect a deceleration error that is caused due to change of the safely-limited speed
at the start of or during SLS. If you have changed the safely-limited speed at the start of or during SLS, and
the time set in this parameter has elapsed with the command/FB speed exceeding the safely-limited speed,
a safe stop (SS1 or STO) is executed. When set to 0, the detection time is treated as 200(ms).
---Setting range---
0 to 99999 (ms)
(PR)
#51101
SF_Disable
Disable smart safety observation
(PR)
#51102
SF_Stoptype
Stop method at error
(PR)
#51103-
51106
SLS_Speed1-4
SLS speed tolerance1-4
(PR)
#51107-
51122
SLS_Override1-16
SLS speed overrid 1-16
(PR)
#51123
SLS_Clamp
SLS speed clamp ratio
#51124
SLS_T1
SLS detection delay time
#51125
SLS_T2
SLS deceleration observation time
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......