M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
289
IB-1501279-H
15.12 High-accuracy Control Axis Parameters
Set the rapid traverse feedrate for each axis.
(Note) The maximum value to be set depends on the machine specifications.
---Setting range---
1 to 1000000 (mm/min)
Set the maximum cutting feedrate for each axis.
Even if the feedrate in G01 exceeds this value, the clamp will be applied at this feedrate.
---Setting range---
1 to 1000000 (mm/min)
Set a feed forward gain for pre-interpolation acceleration/deceleration.
The larger the set value, the smaller the theoretical control error will be. However, if a machine vibration oc-
curs, set the smaller value.
---Setting range---
0 to 200 (%)
Set a feed forward gain for G00 pre-interpolation acceleration/deceleration.
The larger the setting value, the shorter the positioning time during in-position checking.
If a machine vibration occurs, set the smaller value.
---Setting range---
0 to 200 (%)
Set the minimum clamp speed for corner deceleration in the high-accuracy control mode. Normally set "0".
(Note) This parameter is invalid during SSS control.
---Setting range---
0 to 1000000 (mm/min)
Set the rapid traverse rate for each axis in the high-accuracy control mode. "#2001 rapid" will be used when
"0" is set.
---Setting range---
0 to 1000000 (mm/min)
Set the cutting feed maximum speed for each axis in the high-accuracy control mode. "#2002 clamp" will be
used when "0" is set.
---Setting range---
0 to 1000000 (mm/min)
#2001
rapid
Rapid traverse rate
#2002
clamp
Cutting feedrate for clamp function
#2010
fwd_g
Feed forward gain
#2068
G0fwdg
G00 feed forward gain
#2096
crncsp
Minimum corner deceleration speed
#2109
Rapid (H-precision)
Rapid traverse rate for high-accuracy control mode
#2110
Clamp (H-precision)
Cutting feed clamp speed for high-accuracy control
mode
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......