16.6 Absolute Position Detection Parameters
Select the absolute position zero point alignment method.
0: Not absolute position detection
1: Stopper method (push against mechanical stopper)
2: Marked point alignment method I (The grid point is the reference position.)
3: Dog-type (align with dog and near point detection switch)
4: Marked point alignment method II (The position with which the mark was aligned is the reference posi-
tion.)
9: Simple absolute position (Not absolute position detection, but the position when the power is turned off
is registered.)
Select the direction of the grid point immediately before the machine basic position (basic point of detector)
in the marked point alignment.
0: Positive direction
1: Negative direction
Set the tolerable range of travel distance (deviation distance) while the power is turned OFF.
If the difference of the positions when the power is turned OFF and when turned ON again is larger than this
value, an alarm will be output.
Set "0" to omit the check.
---Setting range---
0 to 99999.999 (mm)
Set the current limit value during the stopper operation in the dogless-type absolute position detection.
The setting value is the ratio of the current limit value to the rated current value.
---Setting range---
0 to 100 (%)
Set the feedrate for the automatic initial setting during stopper method.
---Setting range---
1 to 999 (mm/min)
Set the approach distance of the stopper when deciding the absolute position basic point with the stopper
method.
After using stopper once, the tool returns with this distance, and then use stopper again.
---Setting range---
0 to 999.999 (mm)
Set the positive direction width where the near reference position signal is output.
When set to "0", the value is the same as #2218 SV018(PIT).
(Note) When "#1240 set12/bit2" is ON, a magnification (C: 10-fold, D: 100-fold, E:1000-fold) corresponding
to the input setting increment ("#1003 iunit") will be applied to the setting value.
---Setting range---
0 to 999.999 (mm)
(Input setting increment applied)
(PR)
#2049
type
Absolute position detection method
#2050
absdir
Basic point of Z direction
#2051
check
Check
#2054
clpush
Current limit (%)
#2055
pushf
Push speed
#2056
aproch
Approach
#2057
nrefp
Near zero point +
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......