M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
125
IB-1501279-H
Details
An address not listed in the specifications has been used.
Remedy
Correct the program address.
Correct the parameter settings.
Check the specifications.
Details
The command format in the program is not correct.
Remedy
Correct the program.
Details
The commanded G code is not in the specifications.
An illegal G code was commanded during the coordinate rotation command.
G51.2 or G50.2 was commanded when the rotary tool axis No. (the parameter "#1501polyax") was set to
"0".
G51.2 or G50.2 was commanded when the tool axis was set to the linear axis (the parameter "#1017 rot"
= 0).
Remedy
Check and correct the G code address in the program.
Check the parameter setting values.
Details
The setting range for the addresses has been exceeded.
Remedy
Correct the program.
Details
"EOR" has been read during tape and memory mode.
Remedy
Enter the M02 and M30 command at the end of the program.
Enter the M99 command at the end of the subprogram.
Details
"0" has been specified for program or sequence No.
Remedy
Designate program Nos. within a range from 1 to 99999999.
Designate sequence Nos. within a range from 1 to 99999999.
Details
"/n" has been issued while the optional block skip addition is not in the specifications.
Remedy
Check the specifications.
P32
Illegal address
P33
Format error
P34
Illegal G code
P35
Setting value range over
P36
Program end error
P37
O, N number zero
P38
No spec: Add. Op block skip
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......