M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
27
IB-1501279-H
Details
Cutting feed is in wait state until synchronization is completed.
Remedy
Wait for the synchronization to end.
Details
There is a mistake in the settings of mixed control axis parameters (crsax [1] to [8]).
Mixed control was attempted within one and the same part system.
Any of the parameter settings is disabling mixed control.
Remedy
Check the parameter settings for mixed synchronization control.
Details
Mixed synchronization control was commanded for a part system in which mixed synchronization control is dis-
abled as shown below.
During nose R compensation mode
During pole coordinate interpolation mode
During cylindrical interpolation mode
During balance cut mode
During fixed cycle machining mode
During facing turret mirror image
During constant surface speed control mode
During hobbing mode
During axis name switch
During interference check III alarm (interference detection, interference alarm area intrusion or interfer-
ence warning area intrusion)
An axis was transferred to another part system, and mixed control was attempted with the part system's max-
imum number of control axes exceeded.
An axis was removed from the part system, and mixed control was attempted with the part system's number of
axes zero.
Another axis exchange was attempted to the axis which was already transferred to another part system for
mixed control.
Mixed control was attempted with an axis of a part system not in automatic operation.
Remedy
Correct the program.
Details
"Synchronous control operation method" was set (with R2589) when the mode was not the C axis mode.
"Synchronous control operation method" was set (with R2589) in the zero point not set state.
Mirror image is disabled.
External mirror image or parameter mirror image was commanded during facing turret mirror image.
You have set the "Synchronous control operation method" (R2589) of multiple axis synchronization, although
the multiple axis synchronization control cannot be used.
Remedy
Set the contents of the R2589 register to "0".
Correct the program and parameters.
Details
Synchronous control start/cancel command was issued when the start/cancel is disabled.
Remedy
Correct the program and parameters.
M01
Sp-Sp polygon cut interlock
1033
M01
Mixed sync ctrl prmtr illegal
1034
M01
Mixed sync ctrl disable modal
1035
M01
Synchro ctrl setting disable
1036
M01
Synchro start/cancel disable
1037
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......