M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
439
IB-1501279-H
Set the remote I/O device to input the observation speed change signal 2 during executing the safety obser-
vation function.
When set to "0", there is no observation speed change signal input.
Therefore "X0" cannot be used as safety observation signal device.
---Setting range---
0000 to 02FF (HEX)
Specify the intervals of accumulating power consumption to create the history.
The accumulated power consumption history can be obtained according to this parameter along with "#1392
StartTimeIPC" (Power consumption accumulation start time).
When 0 is set, power consumption is not accumulated.
---Setting range---
0 to 999(hr)
Specify the fixed power consumption of the drive system.
This value is used for calculating the power consumption.
---Setting range---
0 to 99999999(W)
Enable the multi-step speed monitor.
0: Disable the multi-step speed monitor
1: Enable the multi-step speed monitor
* When enabling the multi-step speed monitor, setting values for SV238, SV239, SP238 and SP239 will be
ignored.
Set the remote I/O device to input the observation speed change signal 3 during executing the safety obser-
vation function.
When set to "0", there is no observation speed change signal input.
Therefore "X0" cannot be used as safety observation signal device.
---Setting range---
0000 to 02FF (HEX)
Select whether to apply smoothing check method to a cutting block for deceleration check, when deceleration
check method is selected individually for G0 and G1 (when "#1306 InpsTyp" = 1).
0 : Follow the setting of Aux07/BIT1
1 : Apply smoothing check method
Specify the number of the display's rear USB ports occupied by a machine tool builder. Using this setting the
control determines the drive to be used for the front SD and USB memory.
(Note) This parameter is enabled for a Windows-based display of M800W/M80W.
---Setting range---
0 to 6
Enable the function of Data protection by user's level.
0: Use a machine user password to switch the protection of each operation (same as the conventional
models)
1: Switch the protection according to the protective levels (0 to 7) specified for each operation through the
protection setting screen
(Note) You are authorized to change this parameter from 1 to 0 only if your operation level is the same or
higher than that of "Available level" on the protection setting screen.
(PR)
#1370
S_Sig2
Safety observation signal device 2
(PR)
#1371
PwrIntegIntvl
Power consumption accumulation interval
#1372
DrvBasePwr
Fixed drive system power consumption
(PR)
#1373
mstpssc
Multi-step speed monitor enabled
(PR)
#1379
S_Sig3
Safety observation signal device 3
#1389
G1SmthChk
Smoothing check method in cutting block
(PR)
#1390
BackUSBUseNum
Number of backside USB ports occupied
(PR)
#1391
User level protect
Enable Data protection by user's level
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......