M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
154
IB-1501279-H
Details
A travel command for exponential interpolation was issued during mirror image for facing tool posts.
Remedy
Correct the program.
Details
The identification No. specified in the address B of G122 or G144 is that of the part system where G122
is given.
The identification No. specified in the sub part system control I command (G122) is not set in the parameter
#12049 SBS_no.
Remedy
Change the address B of G122 or G144 to be any identification No. other than that of the part system
where G122 is given.
Select the identification No. for the sub part system control I command (G122) from among the available
Nos.
Specify the identification No. you wish to use for the sub part system control I command (G122) in the pa-
rameter #12049 SBS_no.
Details
G122 or G144 has been given together with any other G code command in a block.
Remedy
Do not command G122 or G144 together with any other G code command in a block.
Details
G122 or G144 has been commanded in any of the following modes.
User macro modal call (G66, G66.1)
High-speed mode (G5, G5.1)
Remedy
Cancel the following modes before commanding G122 or G144.
User macro modal call (G66, G66.1)
Fixed cycle mode
High-speed mode (G5, G5.1)
Details
High-speed mode command (G5, G5.1) has been given in a sub part system.
Remedy
Do not use the high-speed mode (G5, G5.1) in a sub part system.
Details
Specified the device other than R register/D register.
Specified the odd numbered device when 4 byte is specified.
Specified the device number that is out of the command range.
Specified the data length that is out of the command range.
Specified the bit number that is out of the command range.
Omitted the device number.
Omitted the project number after ",P".
Omitted the data length after ",".
Omitted the bit number after ".".
Remedy
Check the program.
P612
Exponential function error
P650
Sub sys identification # error
P651
Other G code in sub sys block
P652
Illegal mode (sub part system)
P653
Illegal G code (sub part sys)
P656
Illegal PLC device
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......