M800/M80/E80/C80 Series Alarm/Parameter Manual
14 Multi CPU Errors (A) [C80]
178
IB-1501279-H
Details
Data was not sent correctly with TCP/IP.
Remedy
Check the settings for connection with the external device.
Check the operation of the external device or switching hub.
Since there may be congestion of packets on the line, send data after a certain period of time.
Check if the connection cable is disconnected.
Check that there is no connection failure with the switching hub.
Execute the PING test, and if the test was completed with an error, take the corrective action.
Details
Unsent data found, but could not be sent.
Remedy
Check the settings for connection with the external device.
Check the operation of the external device or switching hub.
Since there may be congestion of packets on the line, send data after a certain period of time.
Check if the connection cable is disconnected.
Check that there is no connection failure with the switching hub.
Execute the PING test, and if the test was completed with an error, take the corrective action.
Details
A moderate error has been notified from the intelligent function module connected.
Remedy
Check the detailed information (system configuration information) of the error by executing module diag-
nostics using the engineering tool, identify the error module, and eliminate the error cause.
Details
An inter-module synchronous signal error has been notified from the intelligent function module connect-
ed.
Remedy
Check the detailed information (system configuration information) of the error by executing module diag-
nostics using the engineering tool, identify the error module, and eliminate the error cause.
Details
A moderate error has been notified from another CPU module.
Remedy
Check the detailed information (system configuration information) of the error by executing module diag-
nostics using the engineering tool, identify the error module, and eliminate the error cause.
Check the mounting status and reset status of other CPU modules.
Details
The execution interval of a synchronous interrupt program has exceeded the set value.
The run of a multiple CPU synchronous interrupt program (I45) has not finished within the multiple CPU
fixed scan communication period.
Remedy
Check the detailed information (time information) in the module diagnostics to verify its value (time), and
take the following actions:
(1) Review the processing details on the multiple CPU synchronous interrupt program so that its processing
is to be completed within the period specified in the fixed scan interval setting.
(2) Set the period specified in the fixed scan interval setting to an appropriate value.
A01
TCP/IP send failed
1166
A01
Unsend data send error
1167
A01
Module moderate error
1200
A01
Module moderate error
1210
A01
Another CPU module moderate error
1220
A01
Multiple CPU synchronization processing error
1260
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......