M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
440
IB-1501279-H
Specify when to start accumulating power consumption to create the history.
The accumulated power consumption history can be obtained according to this parameter along with "#1371
PwrIntegIntvl" (Power consumption accumulation interval).
---Setting range---
0 to 23 (o'clock)
Specify the efficiency for calculating power consumption.
This value is used for calculating the drive system power consumption.
When 0 is set, the efficiency is treated as 70(%).
If the drive system power consumption computed by the NC is different from that measured by a measuring
device, this parameter is used to adjust the drive system power consumption of the NC.
---Setting range---
0 to 100 (%)
Specify the connection destination of the 1st handle.
bit F to 8: Remote I/O unit station 1 to 40(HEX)
bit 7 to 4: Handle connection destination
0: CNC unit
1 to 2: Remote I/O unit
5: Expansion unit
F: Operation panel I/O unit
bit 3 to 0: Handle connection channel 1 to 3 (3 is only valid for operation panel)
(Ex)
0001: Handle 1 connected to the CNC unit
2421: Handle 1 of 36th station for remote I/O unit connected to RIO2
00F3: Handle 3 of operation panel I/O unit connected to RIO3
(Note 1) When the specified destination is not implemented, handle movement is not performed.
(Note 2) When all the H1_pno to H3_pno are set to 0000, handles are automatically allocated.
Other than above, 0000 setting is the same connection as 0001 setting.
---Setting range---
0x0000 to 0xFFFF
Specify the connection destination of the 2nd handle.
bit F to 8: Remote I/O unit station 1 to 40(HEX)
bit 7 to 4: Handle connection destination
0: CNC unit
1 to 2: Remote I/O unit
5: Expansion unit
F: Operation panel I/O unit
bit 3 to 0: Handle connection channel 1 to 3 (3 is only valid for operation panel)
(Ex)
0001: Handle 1 connected to the CNC unit
2421: Handle 1 of 36th station for remote I/O unit connected to RIO2
00F3: Handle 3 of operation panel I/O unit connected to RIO3
(Note 1) When the specified destination is not implemented, handle movement is not performed.
(Note 2) When all the H1_pno to H3_pno are set to 0000, handles are automatically allocated.
Other than above, 0000 setting is the same connection as 0001 setting.
---Setting range---
0x0000 to 0xFFFF
(PR)
#1392
StartTimeIPC
Power consumption accumulation start time
#1393
Efficiency(PwrCal)
Efficiency for power consumption computation
(PR)
#1395
H1_pno
1st handle selection
(PR)
#1396
H2_pno
2nd handle selection
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......