M800/M80/E80/C80 Series Alarm/Parameter Manual
14 Multi CPU Errors (A) [C80]
194
IB-1501279-H
Details
When the boot function is executed, the security key registered in the CPU module (or extended SRAM
cassette) does not match the one that locks the boot source program.
When the boot function is executed, the security key is not registered in the CPU module (or extended
SRAM cassette) even though the boot source program is locked with the security key.
Remedy
Check and correct the security key setting.
Delete the boot setting.
Details
The total number of points of local and global pointers used in the program exceeded the points set in the
CPU parameters (pointer device area).
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
Check and correct the pointer device area point setting in the CPU parameters.
Details
The total number of points of pointertype labels used in the program exceeded the points set in the CPU
parameters (label assignment area).
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
Check and correct the pointer-type label assignment area point setting in the CPU parameters.
Details
Multiple global pointers with the same number are used in the program. (The pointer numbers are over-
lapping.)
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
Details
Multiple local pointers with the same number are used in the program. (The pointer numbers are overlap-
ping.)
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
Details
The interrupt pointer numbers used in the files are overlapping.
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
A01
Boot function execution error
3005
A01
Pointer setting error
3300
A01
Pointer setting error
3301
A01
Pointer setting error
3302
A01
Pointer setting error
3303
A01
Interrupt pointer setting error
3320
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......