bit0: Mirror image operation
Select the type of mirror image operation.
0: Type 1
- The program mirror image, external mirror image, and parameter mirror image are exclusive to each other.
- An increment command moves the image to the position indicated by the travel amount with the sign in-
verted.
1: Type 2
- Mirror image operation is enabled when the program mirror image (G51.1) command is issued or when
the external signal or parameter is ON.
- An increment command moves the image to the position determined by applying the mirror image to the
absolute program coordinates.
bit1: Address specifying fixed cycle repetition count (for M system only)
Select the address that specifies the fixed cycle repetition count.
0: Address L only (Default)
1: Addresses K and L
If addresses K and L are specified simultaneously, the data at address K will be used for operation.
bit2: F-command unit
(M system)
Specify the unit to be used if a thread cutting lead command contains no decimal point.
* This setting is independent of the input unit.
0: Type 1 (conventional specifications)
F1 : 1 mm/rev, 1 inch/rev
1: Type 2
F1 : 0.01 mm/rev, 0.0001 inch/rev
(L system)
Specify the unit to be used if a synchronous feed or thread cutting lead command contains no decimal
point.
0: Type 1 (conventional specifications)
[Input unit B] F1 : 0.0001 mm/rev, 0.000001 inch/rev
[Input unit C] F1 : 0.00001 mm/rev, 0.0000001 inch/rev
1: Type 2
F1 : 0.0001 mm/rev, 0.000001 inch/rev
* Type 2 is independent of the input unit.
bit3: G-code group for unidirectional positioning (for M system only)
Select the G-code group for unidirectional positioning.
0: Unmodal G code (group 00)
1: Modal G code (group 01)
Related parameter: "#8209 G60 Shift" (Set the last positioning direction and distance for each axis ap-
plicable when the unidirectional positioning command is issued.)
bit4: Operation by independent G40 command
Select whether the radius compensation vector is canceled by the independent G40 command.
0: Type 1 (conventional specification) (Default)
The radius compensation vector will be canceled by the independent G40 command.
1: Type 2
The radius compensation vector won't be canceled by the independent G40 command: it will be can-
celed by the next travel command for the radius compensation plane.
bit5: Cut start position (for L system only)
Select the position from where cutting begins in a fixed cycle for compound lathe.
0: Conventional specification (Default)
The cut start position will be determined by the final shaping program.
1: Extended specification
The cut start position will be determined from the cycle start point.
(PR)
#1271
ext07
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......