M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
356
IB-1501279-H
Set the length within the orthogonal coordinate of the inclined axis, a side of the triangle formed with the in-
clination angle.
---Setting range---
-9999.999 to 9999.999
Set the actual length of the base axis corresponding to the inclined axis, a side of the triangle formed with
the inclination angle.
---Setting range---
-9999.999 to 9999.999
Set the actual length of the inclined axis, a side of the triangle formed with the inclination angle.
---Setting range---
-9999.999 to 9999.999
Set the upper limit value of the feedrate when the external deceleration signals are enabled.
---Setting range---
1 to 999999 (mm/min)
Specify the number of the rotational tool axis (servo axis) used for polygon machining (G51.2).
Set "0" when not using polygon machining (spindle-servo axis), or when using spindle-spindle polygon ma-
chining.
A value exceeding the base specification parameter "#1002 axisno" cannot be specified.
This parameter is valid when the G code system is 6 or 7 ("7" or "8" is set in base specification parameter
"#1037 cmdtyp").
---Setting range---
0 to controlled axis number
Select whether to perform a deceleration check when the travel direction is changed from G1 to G0.
0: Not perform
1: Perform
Select whether to perform a deceleration check when the travel direction is changed from G1 to G1.
0: Not perform
1: Perform
Select whether the check is carried out at the specified position in manual second reference position return
mode upon completion of spindle orientation or at second reference position return interlock signal.
0: Upon completion of spindle orientation
1: At second reference position return interlock signal
Set the maximum value up to which the F 1-digit feedrate can be changed.
---Setting range---
0 to 1000000 (mm/min)
Set the constant that determines the speed change rate per manual handle graduation in F 1-digit feedrate
change mode.
---Setting range---
0 to 32767
(PR)
#1213
proaxy
Side 1 of inclination angle (for L system only)
(PR)
#1214
macaxy
Side 2 of inclination angle (for L system only)
(PR)
#1215
macaxx
Side 3 of inclination angle (for L system only)
#1216
extdcc
External deceleration level
#1501
polyax
Rotational tool axis number (for L system only)
#1502
G0Ipfg
G1 -> G0 deceleration check
#1503
G1Ipfg
G1 -> G1 deceleration check
#1505
ckref2
Second reference position return check
#1506
F1_FM
Upper limit of F1-digit feedrate
#1507
F1_K
F 1-digit feedrate change constant
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......