M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
28
IB-1501279-H
Details
A travel command was issued to a synchronous axis in synchronous control.
Remedy
Correct the program.
Details
When the parameter "#1146 Sclamp" has been set to "1", the constant surface speed command (G96)
was issued to the spindle which is not selected for the spindle speed clamp command (G92/G50) under
Multiple spindle control II.
When the parameter "#1146 Sclamp" has been set to "0", both the G96 (Constant surface speed control
ON) modal and the pindle forward or reverse rotation signal have turned ON for the spindle, on which the
speed clamp command is disabled.
Remedy
Press the reset key and carry out the remedy below.
Issue the G92/G50 command to the spindle that is to be used for the constant surface speed control.
Details
There is a mistake in the setting of the superimposition control base axis parameter (#2089 bsax_pl).
Superimposition control is not available under the current parameter settings.
Remedy
- Correct the parameter.
Details
After a single block stop or automatic operation pause was executed during single block stop operation be-
tween part systems, cycle start has not been performed on either part system.
Remedy
Perform cycle start for all the part systems where a single block stop or automatic operation pause was exe-
cuted.
Details
Phase-Z detection speed has not been set in "#3109 zdetspd".
Remedy
Set the phase-Z detection speed in "#3109 zdetspd".
Details
Setting of Interference check across part systems is incorrect.
Remedy
Correct the setting of Interference check across part systems.
Details
Interference is already occurring on the set interfering object.
Remedy
Turn OFF the interference check valid signal, moving the axis to a position where the interfering objects
do not collide each other, and then restart Interference check across part systems.
M01
Move cmnd invld to synchro ax
1038
M01
No spindle speed clamp
1043
M01
Cont ax superimpos II prm illg
1044
M01
Sync error btwn part systems
1045
M01
Z detect speed parameter error
1049
M01
Intrf chck across sys: Set err
1050
M01
Intrf chck across sys: Area AL
1051
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......