16.5 Zero Point Return Parameters
Set a rapid traverse rate for the dog type reference position return command.
This is not used for the distance-coded reference position detection.
---Setting range---
1 to 1000000 (mm/min)
Set up the speed of approach to the reference point in the reference point return command. This speed is
attained after the system stops with deceleration by dog detection.
In the distance-coded reference position detection, the set value will be applied from the start of reference
position establishment.
(Note) The G28 approach speed unit is (10°/min) only when using the Z-phase type encoder (#1226 aux10/
bit3=1) for the spindle/C-axis reference position return type. The same unit is used for both the micrometric
and sub-micrometric specifications.
---Setting range---
1 to 60000 (mm/min)
Set the distance from the electrical zero-point detection position to the reference position.
This is not used for the distance-coded reference position detection.
(Note 1) When "#1240 set12/bit2" is ON, a magnification (C: 10-fold, D: 100-fold and E: 1000-fold) corre-
sponding to the input setting unit ("#1003 iunit") will be applied to the setting value.
(Note 2) The sign of setting value is will be following: the direction of "#2030 dir (-) Reference position direc-
tion (-)" is plus, and the opposite direction is minus.
(Note 3) When set value is set to minus, the axis moves to electrical zero-point detection position at first and
then moves in opposite direction.
---Setting range---
-99.999 to +99.999 (mm)
Set the distance where the grid point will be ignored when near-point dog OFF signals are close to that grid
point during reference position return.
The grid mask is valid for one grid.
This is not used for the distance-coded reference position detection.
---Setting range---
0.000 to 99.999 (mm)
#2025
G28rap
G28 rapid traverse rate
#2026
G28crp
G28 approach speed
#2027
G28sft
Reference position shift distance
#2028
grmask
Grid mask amount
Grid
Near-point dog
Grid mask setup distance
Axis speed
Position
(Detector F/B)
Electrical zero point
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......