M800/M80/E80/C80 Series Alarm/Parameter Manual
3 Servo/Spindle Alarms (S)
61
IB-1501279-H
(1) Drive unit warning
(Note1) Definitions of terms in the table are as follows.
Main side encoder: Encoder connected to CN2
Sub side encoder: Encoder connected to CN3
(Note 2) Resetting methods
* : Automatically reset once the cause of the warning is removed.
NR: Reset with the NC RESET button. This warning can also be reset with the PR and AR resetting conditions.
PR: Reset by turning the NC power ON again. This warning can also be reset with the AR resetting conditions.
When the control axis is removed, this warning can be reset with the NC RESET button. (Excluding warning 93.)
AR: Reset by turning the NC and servo drive unit power ON again.
(Note 3) Servo and spindle motor do not stop when the warning occurs.
(Note 4) When an emergency stop is input, servo and spindle motor decelerate to a stop. (When SV048, SV055 or SV056 is set for
servo and when SP055 or SP056 is set for spindle.)
Dual signal warning (A4)
No.
Name
Details
Reset
method
Stop
method
96 Scale feedback error
An excessive difference in feedback amount was detected between the
main side encoder and the MPI scale in MPI scale absolute position
detection system.
*
-
97 Scale offset error
An error was detected in the offset data that is read at the NC power-ON in
MPI scale absolute position detection system.
PR
-
9B Incremental encoder/
magnetic pole shift warning
The difference between the magnetic pole position after the phase Z has
been passed (magnetic pole shift amount:SV028) and the initially detected
position is excessive in the built-in motor's incremental control system.The
magnetic pole is controlled by the initial detection value.
*
-
9E Absolute position encoder:
Revolution counter error
An error was detected in the revolution counter data of the absolute
position encoder. The accuracy of absolute position is not guaranteed.
*
-
9F Battery voltage drop
The battery voltage to be supplied to the absolute position encoder is
dropping.
NR
-
A3 In initial setup of ABS position
This warning is detected until the axis reaches the reference position during
the initial setup of the distance-coded reference check function. This
warning turns OFF after the axis has reached the position, thus set the
value displayed on the drive monitor to the parameter.
PR
-
A4 Dual signal warning
An input was detected in the signal related to the dual signal.
Refer to "Dual signal warning (A4)" for details.
*
-
A6 Fan stop warning
A cooling fan in the drive unit stopped.
*
-
E0 Overregeneration warning
Over-regeneration detection level exceeded 80%.
*
-
E1 Overload warning
A level of 80% of the Overload 1 alarm state was detected.
*
-
E4 Parameter warning
An incorrect set value was detected among the parameters send from the
NC in the normal operation.
*
-
E6 Control axis detachment warning A control axis is being detached. (State display)
*
-
E7 NC emergency stop
In NC emergency stop. (State display)
*
Dec stop
enabled
E8
to
EF
Power supply warning
The power supply unit detected a warning.
The error details are different according to the connected power supply unit.
Refer to "Power supply warning".
*
-
*EA:
Dec stop
enabled
No.
Name
Sub info
Details
00A4.00
Dual signal warning
Axis name
The system has been set in the STO state. The STO state is also entered at
the time of emergency stop, but in this case, this warning will not appear
because the emergency stop has priority.
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......