M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
8
IB-1501279-H
Details
Chopping mode has been entered while the chopping axis has not completed reference position return.
All axes interlock has been applied.
Remedy
Reset the NC or disable the "chopping" signal, and then carry out the reference position return.
Details
The synchronization error of the master and slave axes exceeded the allowable value under synchronous con-
trol.
A deviation exceeding the synchronization error limit value was found with the synchronization deviation detec-
tion.
Remedy
Select the correction mode and move one of the axes in the direction in which the errors are reduced.
Check the parameter "#2024 synerr".
Increase the allowable value or reset it to "0" (check disabled).
When using simple C-axis synchronous control, set the contents of the R2589 register to "0".
Details
Synchronous tapping command was issued when the spindle select signals (SWS) for all spindles were OFF
in the multiple-spindle control II.
Remedy
Turn ON the spindle select signal (SWS) responding to the tapping spindle before performing the synchro-
nous tapping command.
Details
Synchronous tapping command was issued when the spindle that the spindle select signal (SWS) was ON was
not serially connected in the multiple-spindle control II.
Remedy
Make sure the spindle select signal (SWS) for the responding spindle is ON.
Consider the machine construction when issuing the command.
Details
Asynchronous tapping command was issued when M code of the spindle forward/reverse run command, set
by the parameter "#3028 sprcmm", was one of the followings in the multiple-spindle control II.
M0, M1, M2, M30, M98, M99, or M198
M code No. that commands to enable/disable the "macro interrupt" signal
Remedy
Correct the parameter "#3028 sprcmm" (Tap cycle spindle forward run/reverse run M command) setting.
Details
The command for the pitch or the number of threads is not correct in the synchronous tapping command of the
multiple-spindle control II.
The pitch is too small for the spindle rotation speed.
Thread number is too large for the spindle rotation speed.
Remedy
Correct the pitch, number of threads or rotation speed of the tapping spindle.
M01
Chopping axis R-pnt incomplete
0050
M01
Synchronous error excessive
0051
M01
No spindle select signal
0053
M01
No spindle serial connection
0054
M01
Spindle fwd/rvs run para err
0055
M01
Tap pitch/thread number error
0056
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......