M800/M80/E80/C80 Series Alarm/Parameter Manual
2 Stop Codes (T)
43
IB-1501279-H
Details
A block stop command was issued in the user macro program.
Remedy
Press the CYCLE START switch to resume the automatic operation.
Details
Automatic mode changed to another automatic mode.
Remedy
Return to the original automatic operation mode, and press the CYCLE START switch to resume the au-
tomatic operation.
Details
MDI operation has ended the last block.
Remedy
Set the MDI operation again, and press the CYCLE START switch to start the MDl operation.
Details
The interlock signal, which locks the block start, is ON.
Remedy
Correct the sequence program.
Details
The interlock signal, which locks the block cutting start, is ON.
Remedy
Correct the sequence program.
Details
One of the following commands was issued during the safe speed clamp:
thread cutting, synchronous tapping, cross machining, superimposition control, tool center point control or SSS
control.
Remedy
Turn ON the safely-limited speed monitoring request signal before performing the operation.
Perform the operation with the door closed.
Details
The "inclined axis control: No Z axis compensation" signal has turned ON or OFF during the program operation.
Remedy
Press the CYCLE START switch to resume the automatic operation.
Details
The "NC axis control selection" signal was turned OFF while a NC axis was traveling.
Remedy
Turn the "NC axis control selection" signal ON and press the CYCLE START switch to resume the auto-
matic operation.
T03
Block stop cmnd in user macro
0302
T03
Operation mode changed
0303
T03
MDI completed
0304
T03
Block start interlock
0305
T03
Cutting blck start interlock
0306
T03
Safe speed clamp is ON
0308
T03
Inclined Z offset change
0310
T03
Aux axis changeover error
0330
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......