M800/M80/E80/C80 Series Alarm/Parameter Manual
2 Stop Codes (T)
41
IB-1501279-H
Details
Cycle start was executed during operation error where cycle start cannot be executed.
Remedy
After canceling operation error, execute cycle start.
Details
Cycle start is disabled because the axis in SBT warning exists in the system.
Remedy
After cancelling the SBT warning, execute the cycle start.
Details
Automatic start is not possible because the setting of setup parameters is enabled.
Remedy
Refer to the manual issued by the machine tool builder.
Details
Automatic start was attempted while a file was being deleted/written.
Remedy
Wait for the file to be deleted/written and then execute the automatic start.
Details
Automatic start is not possible because the valid term has been expired.
Remedy
Obtain a decryption code from the machine tool builder and input it in the NC, then turn the power ON
again.
Details
Cycle start is disabled because the break test is being executed for some axes in the system.
Remedy
Execute cycle start after the break test is completed.
Details
Cycle start is disabled because the axis in brake test exists in the system.
Remedy
After the brake test completed, execute the cycle start.
Details
An axis is at the stroke end.
Remedy
Manually move the axis away from the stroke end limit switch.
Correct the machining program.
Details
An axis is at the stored stroke limit.
Remedy
Manually move the axis.
Correct the machining program.
T01
Cycle start prohibit (OP error)
0177
T01
Cycle start prohibit(SBT warn)
0185
T01
Cycle start prohibit
0190
T01
Cycle start prohibit
0191
T01
Cycle st. prohibit (Term exp'd)
0193
T01
Cycle start disabled (in SBT)
0194
T01
Cycle start prohibit(in SBT)
0197
T02
H/W stroke end axis exists
0201
T02
S/W stroke end axis exists
0202
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......