M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
490
IB-1501279-H
Set the radius of the special diametral axis.
---Setting range---
0 to 99999.999 (mm)
Set a clamp speed for the special diametral axis control.
Set the limit speed of the drive system in this parameter.
---Setting range---
0 to 1000000 (°/min)
(Note) For "#2001 rapid" and "#2002 clamp", set speeds on a machining line.
When the value in "#2176 Special Ax Clamp" is smaller than that in "#2001 rapid", "Special Ax Clamp" value
will be applied to the clamp speed.
Set the acceleration/deceleration time constant for manual feed rate B.
(Note) When set to "0", this parameter will not be used: conventional acceleration/deceleration will be per-
formed.
---Setting range---
0 to 20000 (ms)
Set the door signal input in the drive unit.
Use this parameter only when the axis with a door signal belongs to several door groups.
The correspondence between the door signals and bits are as follows.
bit0 : Door1 signal
bit1 : Door2 signal
If the axis does not receive any door signal, set to "0".
If 0 is set to the axis to which a door signal is input, the setting of #2118 is applied.
Do not turn ON more than one bit.
Only the door signals set in #2118 can be set.
---Setting range---
0000 to 0002 (HEX)
Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note 1) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(mm/min, °/min)
(Note 2) Observation speeds (#2181 to #2186 and #2191 to #2192) need to satisfy the following condition.
If not satisfied, the alarm (Y20 0007) will result.
---Setting range---
0 to 6553500 (mm/min or °/min)
#2175
Special Ax Radius
Special diametral axis radius
#2176
Special Ax Clamp
Special diametral axis clamp speed
#2177
ManualFeedBtL
Time constant for manual feed rate B
(PR)
#2180
S_DIN
Speed observation input door No.
(PR)
#2181
sscfeed1
Observation speed 1
≤
×
sscfeed1
㹼
8
SV002:PC2
32767
SV001:PC1
SV018:PIT
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......