M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
625
IB-1501279-H
[M8]
Set the rotation direction for the table rotating type workpiece-side rotary axis.
The rotation direction specifications vary according to the setting of "#1450 5axis_Spec/bit3" (Select specifi-
cations of rotation direction parameter).
- When "#1450 5axis_Spec/bit3" = "0"
The specifications vary for each function.
- When "#1450 5axis_Spec/bit3" = "1"
The specifications are common to the functions.
0: When the tool motion viewed from the workpiece is in right-hand screw direction, it is taken as the pos-
itive direction.
1: When the tool motion viewed from the workpiece is in left-hand screw direction, it is taken as the positive
direction.
When all axes are at the machine zero point, set the distance in the horizontal axis direction between rotation
centers of the base-side rotary axis and the workpiece-side rotary axis.
---Setting range---
-99999.999 to 99999.999 (mm)
When all axes are at the machine zero point, set the distance in the vertical axis direction between rotation
centers of the base-side rotary axis and the workpiece-side rotary axis.
---Setting range---
-99999.999 to 99999.999 (mm)
When all axes are at the machine zero point, set the distance in the height axis direction between rotation
centers of the base-side rotary axis and the workpiece-side rotary axis.
---Setting range---
-99999.999 to 99999.999 (mm)
Set the error compensation amount in the horizontal axis direction of the table rotating type workpiece-side
rotary axis rotation center.
When table rotating type workpiece side rotary axis is I axis rotation, set the position deviation of J axis rota-
tion.
When table rotating type workpiece side rotary axis is J axis rotation, set the position deviation of K axis ro-
tation.
When table rotating type workpiece side rotary axis is K axis rotation, set the position deviation of I axis ro-
tation.
---Setting range---
-99999.999 to 99999.999 (mm)
(Follow as "#1006 mcmpunit Machine error compensation unit".)
Set the error compensation amount in the vertical axis direction of the table rotating type workpiece-side ro-
tary axis rotation center.
When table rotating type workpiece side rotary axis is I axis rotation, set the position deviation of K axis ro-
tation.
When table rotating type workpiece side rotary axis is J axis rotation, set the position deviation of I axis rota-
tion.
When table rotating type workpiece side rotary axis is K axis rotation, set the position deviation of J axis ro-
tation.
---Setting range---
-99999.999 to 99999.999 (mm)
(Follow as "#1006 mcmpunit Machine error compensation unit".)
#7953
DIR_W2
Rotation direction
#7954
COFSW2H
Horizontal axis rotation center offset
#7955
COFSW2V
Vertical axis rotation center offset
#7956
COFSW2T
Height axis rotation center offset
#7957
CERRW2H
Horizontal axis rotation center error compensation
amount
#7958
CERRW2V
Vertical axis rotation center error compensation
amount
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......