M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
135
IB-1501279-H
Details
Connection to the main spindle unit was not established.
The synchronous tapping was attempted with the spindle not serially connected under the multiple-spindle
control I.
Synchronous tapping command was given to the analog spindle while analog spindle synchronous tapping
was unavailable.
Remedy
Check connection to the main spindle.
Check that the main spindle encoder exists.
Set 1 to the parameter #3024 (sout).
Correct the program.
Details
The pitch or number of threads has not been commanded in the tap cycle of a fixed cycle for drilling command.
Remedy
Specify the pitch data and the number of threads by F or E command.
Details
The pitch or the number of threads per inch is illegal in the tap cycle of the fixed cycle for drilling command.
The pitch is too small for the spindle rotation speed.
The thread number is too large for the spindle rotation speed.
Remedy
Correct the pitch or the number of threads per inch.
Details
Synchronous tapping cycle (G84/G74) was commanded though it is out of specifications.
Remedy
Check the specifications.
Details
S command was issued during synchronous tapping modal.
Remedy
Cancel the synchronous tapping before issuing the S command.
Details
A lathe cutting cycle command was issued though it is out of specifications.
Remedy
Check the specification.
Delete the lathe cutting cycle command.
Details
In the lathe cutting cycle, the specified length of taper section is illegal.
Remedy
Set the smaller radius value than the axis travel amount in the lathe cycle command.
Details
Chamfering in the thread cutting cycle is illegal.
Remedy
Set a chamfering amount not exceeding the cycle.
P182
Synchronous tap error
P183
No pitch/thread number
P184
Pitch/thread number error
P185
No spec: Sync tapping cycle
P186
Illegal S cmnd in synchro tap
P190
No spec: Turning cycle
P191
Taper length error
P192
Chamfering error
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......