M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
631
IB-1501279-H
16.16 PLC Bit Selection
(Note) Even if the data is set in the R register(R7800 to R7897) that corresponds to the PLC side when this parameter
is displayed, the screen will not change.Enter a different screen once, and then select this screen again.
#6449 to #6496 are PLC operation parameters used by MITSUBISHI.
Refer to the PLC Development Manual and the PLC Programming Manual for details.
These bit type parameters are used in the user PLC (ladder).
bit7: Control unit thermal alarm valid
bit6: Setting and display unit thermal management valid (This function may not be available for some NC
models.)
bit5: Set to "0".
bit4: Battery alarm/warning detection disabled
(Note) When the parameter is set to "1", the "Battery alarm" signal and the "Battery warning" signal will
not be turned ON, and the alarm messages will not be displayed.
bit3: Counter C retention
bit2: Integrated timer ST retention
bit1: PLC counter program valid
bit0: PLC timer program valid
bit7: Set to "0".
bit6: External alarm message display (This function may not be available for some NC models.)
bit5: Alarm/operator change (This function may not be available for some NC models.)
bit4: Full screen display of message (This function may not be available for some NC models.)
bit3: Set to "0".
bit2: Operator message valid
bit1: Alarm message display interface
1: R method
0: F method
bit0: Alarm message valid
bit7-4: Set to "0".
bit3:
[M8]
Set to "0".
[C80]
Select the key input switch setting.
0: Key code is processed without going through the sequence program.
1: Key code is processed through the sequence program.
(Note) When this parameter is 1, key data is set in KEYOUT(R212) through a sequence program, and
is enabled. Even if the key data is not changed through a sequence program, make sure to loop-back
the key data read from KEYIN(R8) of the NC to R212 of the PLC. Without this loop-back, the key be-
comes disabled. If the program on the PLC side is at a stop (including a case when STOP is selected
by the RUN/STOP switch), key data does not go through the PLC.
bit2: Built-in edit function edit invalid (This function may not be available for some NC models.)
bit1: Set to "0".
bit0: Built-in edit function valid (This function may not be available for some NC models.)
#6401-6448
R7800-Low - R7823-High
Bit selection
#6449
R7824-Low
Bit selection
#6450
R7824-High
Bit selection
#6451
R7825-Low
Bit selection
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......