M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
30
IB-1501279-H
Details
A manual travel command has been given to the axis being exchanged when manual interruption is disabled
under cross machining control (when "#1435 crsman" = 0).
Remedy
This error can be cancelled by either one of the following operations.
1: Cancel the manual travel command
2: Reset the NC
Details
Arbitrary axis superimposition command has been issued in any part system other than the one that con-
tains either the basic or superimposed axis of arbitrary axis superimposition control.
Arbitrary axis superimposition cancel command has been issued in any part system other than the one
that contains the superimposed axis of arbitrary axis superimposition control.
Remedy
Correct the program so that the arbitrary axis superimposition command is given in an appropriate part
system.
Details
The actual spindle speed has fluctuated exceeding the allowable range, while spindle speed fluctuation detec-
tion (G162) is active.
The number following "S", which is output together with this alarm, indicates the spindle where speed fluctua-
tions were detected.
Remedy
Unnecessarily large load may be applied to the spindle during automatic operation.
Reduce the spindle load.
To prevent this alarm from being output during spindle speed fluctuation detection (G162), set the param-
eter #1242 set14 BIT2 to ON.
Details
Spindle synchronization phase alignment command was issued while the "phase shift calculation request" sig-
nal was ON.
Remedy
Correct the program.
Correct the sequence program.
Details
A function that cannot be used with spindle oscillation was commanded during spindle oscillation.
Remedy
Command the function after finishing spindle oscillation.
Details
Spindle oscillation was commanded during executing a function that cannot be used with spindle oscillation.
Remedy
Command spindle oscillation after finishing the function that cannot used with spindle oscillation.
Details
Spindle oscillation was commanded while a value out of range is set as spindle oscillation amplitude or spindle
oscillation frequency.
Remedy
Check the setting values of the amplitude and frequency.
M01
Cross control axis exists
1102
M01
Arbitrary ax superimp. sys err
1103
M01
Spindle speed fluctuation
1105
M01
Sp synchro phase calc illegal
1106
M01
Illegal cmd in SP oscillation
1108
M01
SP oscillation cmd illegal
1109
M01
SP oscillation set val illegal
1110
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......