M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
387
IB-1501279-H
Select how to handle the absolute position data during automatic handle interrupt.
0: Absolute position data will be renewed if manual ABS switch is ON. If it is OFF, data won't be renewed.
1: Follow the "intabs" state when "#1061 intabs" is enabled
Select how to handle the spindle rotation speed clamp function with the G92/G50S command.
0: G92/G50S command is handled as a clamp command only in the G96 state (during constant surface
speed control).
G92S will be handled as normal S command in G97 state (constant surface speed OFF).
1: The S command in the same block as G92/G50 is constantly handled as a clamp command
Specify the type of spindle min. rotation speed clamp value.
0: Rotation speed setting
1: Output voltage coefficient setting
Set "#3023 smini" according to this type setting.
Select whether to decelerate at the arc entrance or exit.
0: Not decelerate
1: Decelerate
Select whether to perform a deceleration check or in-position check at the hole bottom in a hole drilling cycle.
This parameter is enabled only for a hole drilling cycle in which no dwell command can be issued at the hole
bottom.
0: Perform no deceleration check and in-position check
1: Perform deceleration check
2: Perform in-position check
Not used. Set to "0".
Not used. Set to "100".
Not used. Set to "100".
Not used. Set to "0".
Not used. Set to "0".
Select whether to enable or disable RIO connection detection.
0: Enable
1: Disable
If your I/O consists of only cards such as CC-LINK, setting this parameter to "1" will avoid the RIO commu-
nication cutoff alarm.
Select whether to enable or disable the automatic tuning function.
0: Disable
1: Enable
(Note) Enable this parameter when using MS Configurator.
#1145
I_abs
Manual ABS parameter
#1146
Sclamp
Spindle rotation speed clamp function
#1147
smin_V
Minimum spindle rotation speed clamp type
#1149
cireft
Arc deceleration speed change
#1153
FixbDc
Hole bottom deceleration check
(PR)
#1154
pdoor
#1155
DOOR_m
#1156
DOOR_s
#1157
F0atrn
#1158
F0atno
(PR)
#1163
No rio
RIO connection detection invalid
(PR)
#1164
ATS
Automatic tuning function
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......