M800/M80/E80/C80 Series Alarm/Parameter Manual
5 System Alarms (Z)
89
IB-1501279-H
Details
Acceleration and deceleration time constants are too large.
(This alarm occurs with the stop code (T02 0206).)
Remedy
Set the larger value for "#1206 G1bF(Maximum speed)".
Set the smaller value for "#1207 G1btL(Time constant)".
Set the lower feedrate.
Details
A communication error has occurred on the Fieldbus communication with FCU8-WN563.
[n1: denotes the master station status (in the hexadecimal form).]
00: Offline: In initialization
40: Stop: I/O communication stopped
80: Clear: Resetting the output data of each slave by sending zero data
C0: In operation: In I/O communication
FF: Two Fieldbus expansion units are mounted.
[n2: denotes the error condition (in the hexadecimal form).]
bit0: Control error: Parameter error
bit1: Auto clear error: Communication with all the slave stations was cut because a communication with one
slave station had an error.
bit2: Non-exchange error: A slave station has communication error.
bit3: Fatal error: Communication cannot be continued because of severe network failure.
bit4: Not ready: CNC communication is not ready.
bit5: Timeout error: Timeout is detected in communication with each station.
bit6: Not used
bit7: Not used
FF: Two Fieldbus expansion units are mounted.
[n3: denotes the slave station where communication error has occurred(in the hexadecimal form).]
* FF is indicated when two Fieldbus expansion units are mounted.
[n4: denotes the error number (in the hexadecimal form).]
This shows the communication state with slave station where error is occurring.
For details, refer to "PROFIBUS-DP Specification manual".
Details
The valid term will be expired in less than a week. Remaining valid term is xx days.
Remedy
Obtain a decryption code from the machine tool builder and input it in the NC, then turn the power ON
again.
Details
The valid term has been expired with no decryption code input.
Remedy
Obtain a decryption code from the machine tool builder and input it in the NC, then turn the power ON
again.
Details
A communication error occurred during CC-Link communication using CC-Link unit.
Remedy
Refer to "List of Messages" in CC-Link (Master/Local) Specification manual (BNP-C3072-089).
Details
A cable between CC-Link unit and a device is disconnected or broken.
Remedy
Find the unconnected cable by checking SW0080 to SW0083 and connect it.
Z59
Acc/dec time cnst too large
Z60
Fieldbus communication error
n1 n2 n3 n4
Z64
Valid term soon to be expired
xx
Z65
Valid term has been expired
Z67
CC-Link communication error
Z68
CC-Link unconnected
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......