M800/M80/E80/C80 Series Alarm/Parameter Manual
5 System Alarms (Z)
88
IB-1501279-H
Details
An error occurs in the communication between the control unit and remote I/O unit.
Disconnection of a cable
Fault in remote I/O unit
Fault of power supply to remote I/O unit
The communication interrupted station is displayed in hexadecimal for each RIO channel when an error occurs
in the communication between the control unit and remote I/O unit.
When the control displays a communication stop station, it divides the RIO channel stations (up to 64 stations)
into groups of 8 stations. If any of the 8 stations has the communication stop error, the number is displayed with
the alarm.
Z55 RIO communication stop __ __ __ __ __ __ __ __
(a) (b) (c) (d) (e) (f) (g) (h)
(a)(b): RIO1
(c)(d): RIO2
(e)(f): RIO3
(g)(h): "00" fixed
(a)(b), (c)(d), and (e)(f) indicate the following stations in hexadecimal.
bit0: 1st to 8th stations
bit1: 9th to 16th stations
bit2: 17th to 24th stations
bit3: 25th to 32nd stations
bit4: 33rd to 40th stations
bit5: 41st to 48th stations
bit6: 49th to 56th stations
bit7: 57th to 64th stations
(Example) Stations #1 and #8 of RIO1 and stations #24 and #64 of RIO3 have the communication error.
Z55 RIO communication stop 0100 8400
The RIO error status can be monitored through the R registers on the self diagnostic or I/F diagnostic screen.
Remedy
Check and replace the cables.
Replace the remote I/O unit.
Check the power supply (existence of supply and voltage).
Details
Program memory capacity has been set over the value that can be formatted.
An expansion device/expansion cassette has not mounted after formatting.
The mounted expansion device/expansion cassette is different from the one that was mounted at formatting.
Remedy
Check the followings.
Program memory capacity
Mounting of an expansion device/expansion cassette
APLC release option
Details
A machine tool builder macro program has not been written to FROM after being registered/ edited/ copied/
condensed/ merged/ the number changed/ deleted.
Remedy
Write the machine tool builder macro program to FROM.
The program does not need to be written to FROM unless the editing operations and so on need to be valid
after the NC power OFF.
Z55
RIO communication stop
Z57
System warning
Z58
ROM write not completed
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......