Specify the name of PLC device that is sent to Adapter Implicit (OUT) area. (a=1 to 6)
Example) Y
---Setting range---
Y, M, L, SB, B, SW, D, R, W
Specify the top No. of PLC device that is sent to Adapter Implicit (OUT) area. (a=1 to 6)
If you specify bit device, set it in increments of 16 points.
Example) 200
---Setting range---
Y: 0 to 5F0
M: 0 to 61424
L: 0 to 32752
SB: 0 to 7FF0
B: 0 to EFF0
SW: 0 to 7FFF
D: 0 to 32767
W: 0 to 7FFF
R: 8300 to 9799, 9800 to 9899, 18300 to 19799, 19800 to 19899, 28300 to 29799, 29800 to 29899
Specify the size (bytes) of PLC device that is sent to Adapter Implicit (OUT) area. (a=1 to 6)
Example) 1
---Setting range---
0 to 500 (bytes)
* Up to 500 bytes in total for all areas
Specify the No. of PLC project to which connection status is transferred.
---Setting range---
1 to 6
Specify the name of PLC device to which connection status is transferred.
Example) M
---Setting range---
M, L, SB, B, SW, D, R, W
Specify the top No. of PLC device to which connection status is transferred.
6 bytes of data starting from the specified device No. are occupied.
---Setting range---
M: 0 to 61424
L: 0 to 32752
SB: 0 to 7FF0
B: 0 to EFF0
SW: 0 to 7FFF
D: 0 to 32767
W: 0 to 7FFF
R: 8300 to 9799, 9800 to 9899, 18300 to 19799, 19800 to 19899, 28300 to 29799, 29800 to 29899
#81446+20(a-1)
Imp A1out dev name
Adapter function Implicit Message: PLC device name
(OUT)
#81447+20(a-1)
Imp A1out dev No.
Adapter function Implicit Message: PLC device top No.
(OUT)
#81448+20(a-1)
Imp A1out dev size
Adapter function Implicit Message: PLC device size
(OUT)
#81560
Imp sts Proj No.
Connection status assigned PLC project No.
#81561
Impsts dev name
Connection status assigned PLC device name
#81562
Imp sts dev No.
Connection status assigned PLC device top No.
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......