M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
126
IB-1501279-H
Details
A non-specified G code was commanded.
The selected operation mode is out of the option setting.
The selected operation mode is out of the parameter setting.
Remedy
Check the specifications.
Check the parameter setting values.
Details
When tool radius compensation is executed, there is an error in the pre-read block and so the interference
check is disabled.
Remedy
Reconsider the program.
Details
The combination of G codes in a block is inappropriate.
A part of unmodal G codes and modal G codes cannot be commanded in a same block.
Remedy
Correct the combination of G codes.
Separate the incompatible G codes into different blocks.
Details
A travel command was issued before the execution of the block that had been restart-searched.
Remedy
Carry out program restart again.
Travel command cannot be executed before the execution of the block that has been restart-searched.
Details
Restart search was attempted for a block that comes after any of the following command blocks:
3-dimensional circular interpolation, cylindrical interpolation, polar coordinate interpolation, milling interpola-
tion, tool center point control, simple tool center point control, inclined surface machining, simple inclined sur-
face machining, workpiece installation error compensation, axis name switch, mixed control, machining
condition selection I, sub part system control I, sub part system control II, or direct command mode.
Remedy
Reconsider the restart search position.
Details
Inch/Metric changeover (G20/G21) command was issued while the function is out of specifications.
Remedy
Check the specifications.
Details
The commanded movement distance is excessive (over 2
31
).
Remedy
Correct the command range for the axis address.
P39
No specifications
P40
Pre-read block error
P45
G code combination error
P48
Restart pos return incomplete
P49
Invalid restart search
P50
No spec: Inch/Metric change
P60
Compensation length over
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......