M800/M80/E80/C80 Series Alarm/Parameter Manual
14 Multi CPU Errors (A) [C80]
183
IB-1501279-H
Details
A module that the CPU module cannot recognize is mounted.
The module cannot be recognized because the control CPU setting of the system parameter setting differs
from that of other CPU modules in the multiple CPU system.
Remedy
Mount only applicable modules.
Correct the system parameter settings for the CPU No.2 and later. The settings need to be the same be-
tween all the CPU modules.
The possible cause is a hardware failure of the I/O module or intelligent function module accessed. Please
consult your local Mitsubishi representative.
Details
Overlapping IP addresses have been detected.
Remedy
Check and correct the IP addresses.
Details
An invalid file has been detected.
Remedy
Check the detailed information (drive/file information) of the error by executing module diagnostics using
the engineering tool, select the correct file name, and write the specified file to the CPU module. If the same
error code is displayed again, the possible cause is a hardware failure of the CPU module. Please consult
your local Mitsubishi representative.
Details
The file specified in parameter cannot be created.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and correct the name and size of the file corresponding to the displayed number.
Check the detailed information (drive/file information) of the error by executing module diagnostics using
the engineering tool, and take either of the following action.
(1) Format the corresponding drive.
(2) Delete unnecessary files on the corresponding drive to increase free space.
(3) Unlock the corresponding drive if it is locked.
Details
The CPU module model set to the file using the engineering tool differs from that of the CPU module ac-
tually mounted.
Remedy
Check the detailed information (drive/file information) of the error by executing module diagnostics using
the engineering tool, and correct the CPU module model set to the file in accordance with that of the CPU
module actually mounted.
Details
The system parameter file and CPU parameter file do not exist.
The memory card parameter file or module extension parameter file stored in the memory card cannot be
accessed because the memory card is disable by SM606 (SD memory card forced disable instruction).
Remedy
Write the system parameter file and CPU parameter file to the CPU module.
Turn off SM606. (Cancel the disabled state.)
A01
Module unrecognized
20E0
A01
IP address duplication error
2160
A01
Invalid file
2180
A01
File specification error
21A1
A01
File specification error
21A2
A01
Parameter A error
2200
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...