M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
585
IB-1501279-H
[M8]
Specify the acceleration/deceleration time constant for S command (speed operation mode) to be applied to
the spindle motor (gear 00) that is being protected against increased temperature.
Set the linear acceleration/deceleration time to reach the limit rotation speed (slimit1).
When 0 or any value smaller than "#3101 sp_t1" is set, switchover of the time constant is disabled, and ac-
celeration/deceleration is performed with the time constant "#3101 sp_t1".
---Setting range---
0 to 30000 (ms)
[M8]
Specify the acceleration/deceleration time constant for S command (speed operation mode) to be applied to
the spindle motor (gear 01) that is being protected against increased temperature.
Set the linear acceleration/deceleration time to reach the limit rotation speed (slimit2).
When 0 or any value smaller than "#3102 sp_t2" is set, switchover of the time constant is disabled, and ac-
celeration/deceleration is performed with the time constant "#3102 sp_t2".
---Setting range---
0 to 30000 (ms)
[M8]
Specify the acceleration/deceleration time constant for S command (speed operation mode) to be applied to
the spindle motor (gear 10) that is being protected against increased temperature.
Set the linear acceleration/deceleration time to reach the limit rotation speed (slimit3).
When 0 or any value smaller than "#3103 sp_t3" is set, switchover of the time constant is disabled, and ac-
celeration/deceleration is performed with the time constant "#3103 sp_t3".
---Setting range---
0 to 30000 (ms)
[M8]
Specify the acceleration/deceleration time constant for S command (speed operation mode) to be applied to
the spindle motor (gear 11) that is being protected against increased temperature.
Set the linear acceleration/deceleration time to reach the limit rotation speed (slimit4).
When 0 or any value smaller than "#3104 sp_t4" is set, switchover of the time constant is disabled, and ac-
celeration/deceleration is performed with the time constant "#3104 sp_t4".
---Setting range---
0 to 30000 (ms)
#43086
protect_sp_t1
Acceleration/Deceleration time constant during spindle
protection (Gear: 00))
#43087
protect_sp_t2
Acceleration/Deceleration time constant during spindle
protection (Gear: 01))
#43088
protect_sp_t3
Acceleration/Deceleration time constant during spindle
protection (Gear: 10)
#43089
protect_sp_t4
Acceleration/Deceleration time constant during spindle
protection (Gear: 11)
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......